OSHA SearchOSHA records by employer

Reber Masonry & Restoration LLC: OSHA inspections and violations

Pittsburgh, Pennsylvania · Masonry Contractors · NAICS 238140

5inspections
19citation items
$28,775current penalties
Jan 22, 2026last inspection

OSHA has inspected Reber Masonry & Restoration LLC 5 times in Pennsylvania since 2023.

The latest one began on Jan 22, 2026 as a planned inspection, in Pittsburgh.

Those inspections ended with 19 citation items: 7 serious, 3 repeat and 9 other-than-serious.

Penalties were first proposed at $51,950 and now stand at $28,775, 45% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 15 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Reber Masonry & Restoration LLC averages $5,755 (5 cited inspections).

Reber Masonry & Restoration LLC: OSHA citation items per year, 2023 to 2026
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

274employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Reber Masonry & Restoration LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348704438 OPENED JAN 22, 2026Closed

Planned · Partial · Safety · 25 employees at the site · Closed Jul 16, 2026

1462 Chateau Street, Pittsburgh, PA 15233 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(e)(9)(i) · Scaffolds, general requirements
Serious$2,837$1,900Mar 18, 2026Final
Citation 1, item 1b
29 CFR 1926.451(g)(2) · Scaffolds, general requirements
Serious$0$0Mar 18, 2026Final
Citation 2, item 1
29 CFR 1926.100(a) · Hard hats in construction
Other-than-serious$0$0Mar 18, 2026Final

Inspection 347820581 OPENED OCT 17, 2024Closed

Planned · Partial · Safety · 25 employees at the site · Closed Sep 25, 2025

690 Bower Hill Road, Bridgeville, PA 15017 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(9)(i) · Scaffolds, general requirements
Serious$2,765$1,750Nov 13, 2024Final
Citation 2, item 1
29 CFR 1926.100(a) · Hard hats in construction
Repeat$7,374$4,000Nov 13, 2024Final
Citation 2, item 2
29 CFR 1926.451(g)(2) · Scaffolds, general requirements
Repeat$7,374$4,000Nov 13, 2024Final
Citation 3, item 1
29 CFR 1926.451(f)(6) · Scaffolds, general requirements
Other-than-serious$0$0Nov 13, 2024Final
Citation 3, item 2
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Other-than-serious$0$0Nov 13, 2024Final

Inspection 347719031 OPENED AUG 28, 2024Closed

Planned · Partial · Safety · 25 employees at the site · Closed Sep 22, 2026

215 Dell Avenue, Pittsburgh, PA 15216 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$2,489$1,500Oct 16, 2024Final
Citation 1, item 2
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Serious$4,149$2,500Oct 16, 2024Final
Citation 1, item 3a
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$5,807$3,000Oct 16, 2024Final
Citation 1, item 3b
29 CFR 1926.451(g)(4)(xv) · Scaffolds, general requirements
Serious$0$0Oct 16, 2024Final
Citation 2, item 1
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Repeat$12,905$7,000Oct 16, 2024Final
Citation 3, item 1
29 CFR 1926.451(c)(2)(i) · Scaffolds, general requirements
Other-than-serious$0$0Oct 16, 2024Final
Citation 3, item 2
29 CFR 1926.451(h)(2) · Scaffolds, general requirements
Other-than-serious$0$0Oct 16, 2024Final
Citation 3, item 3
29 CFR 1926.452(c)(3) · Rules for each type of scaffold
Other-than-serious$0$0Oct 16, 2024Final

Inspection 346927155 OPENED AUG 19, 2023Closed

Planned · Partial · Safety · 25 employees at the site · Closed Jan 4, 2024

1600 Termon Avenue, Pittsburgh, PA 15212 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Other-than-serious$0$0Sep 14, 2023Final

Inspection 346921117 OPENED AUG 18, 2023Closed

Planned · Partial · Safety · 25 employees at the site · Closed May 30, 2024

1616 Chateau Street, Pittsburgh, PA 15212 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Other-than-serious$2,678$1,339Sep 18, 2023Final
Citation 1, item 2
29 CFR 1926.451(g)(2) · Scaffolds, general requirements
Other-than-serious$3,572$1,786Sep 18, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(c)(1)

(c) Criteria for supported scaffolds. (1) Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means, as follows:

29 CFR 1926.452 · Rules for each type of scaffold

Other masonry contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.