OSHA SearchOSHA records by employer

Red Noland Cadillac, Inc.: OSHA inspections and violations

Colorado Springs, Colorado · General Automotive Repair · NAICS 811111

1inspections
2citation items
$4,500current penalties
Jan 10, 2018last inspection

OSHA inspectors have visited Red Noland Cadillac, Inc. in Colorado one time.

It opened on Jan 10, 2018 as a planned inspection, in Colorado Springs.

In all, OSHA issued 2 citation items: 2 other-than-serious.

The proposed penalties came to $8,472; today they stand at $4,500, 47% less.

Among repair and personal services employers, the typical cited inspection since 2015 ends with a $1,200 penalty. Red Noland Cadillac, Inc. averages $4,500 across 1 cited inspection.

Red Noland Cadillac, Inc.: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

136employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Red Noland Cadillac, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342871407 OPENED JAN 10, 2018Closed

Planned · Complete · Safety · 18 employees at the site · Closed Feb 16, 2018

990 Motor City Dr, Colorado Springs, CO 80905 · General Automotive Repair · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$3,298$0Jan 29, 2018Final
Citation 1, item 2
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$5,174$4,500Jan 29, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.242(b)

(b) Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(g)(2)(iii)

(iii) Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.

Other general automotive repair employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.