OSHA SearchOSHA records by employer

Red Stag Contractors, LLC: OSHA inspections and violations

Milton, Tennessee · Power and Communication Line and Related Structures Construction · NAICS 237130

1inspections
5citation items
$15,200current penalties
Apr 5, 2018last inspection

OSHA has inspected Red Stag Contractors, LLC once in Tennessee.

The inspection began on Apr 5, 2018 after a fatality or catastrophe, in Milton.

That inspection ended with 5 citation items: 3 serious and 2 other-than-serious.

Penalties were first proposed at $15,200 and still stand at $15,200.

Telecommunications comes up most often in these citations: 3 items under 1910.268.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Red Stag Contractors, LLC averages $15,200 (1 cited inspection).

1 inspection on this page followed a fatal incident.

Red Stag Contractors, LLC: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

339employers cited

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Red Stag Contractors, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343069720 OPENED APR 5, 2018Closed

Fatality or catastrophe · Partial · Safety · 48 employees at the site · Closed Aug 28, 2018

7951 Ruel Mcknight Road, Milton, TN 37118 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Incident on Apr 4, 2018 (fatal): Employee is electrocuted when boom contacts power line

At 3:15 p.m. on April 4, 2018, an employee was standing by as a coworker operated the boom of a truck. The employee was leaning on the boom truck and the coworker was operating the boom truck in close vicinity of an overhead power line. The boom made contact with the energized line, resulting in the employee being electrocuted. The incident investigation determined that the electrical current had run down the boom and through the employee because he was leaning on the truck.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.268(c) · Telecommunications
Serious$4,000$4,000Jun 22, 2018Final
Citation 1, item 2
29 CFR 1910.268(c)(3) · Telecommunications
Serious$4,000$4,000Jun 22, 2018Final
Citation 1, item 3
29 CFR 1910.268(j)(4)(i) · Telecommunications
Serious$5,400$5,400Jun 22, 2018Final
Citation 2, item 1
29 CFR TDLWD RULE 800-01-03-.05(1)(A)1
Other-than-serious$1,500$1,500Jun 22, 2018Final
Citation 2, item 2
29 CFR TDLWD RULE 800-01-03-.05(1)(A)2
Other-than-serious$300$300Jun 22, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.268 · Telecommunications

29 CFR 1910.268(c)

(c) Training. Employers shall provide training in the various precautions and safe practices described in this section and shall insure that employees do not engage in the activities to which this section applies until such employees have received proper training in the various precautions and safe practices required by this section. However, where the employer can demonstrate that an employee is already trained in the precautions and safe practices required by this section prior to his employment, training need not be provided to that employee in accordance with this section. Where training is required, it shall consist of on-the-job training or classroom-type training or a combination of both. The employer shall certify that employees have been trained by preparing a certification record which includes the identity of the person trained, the signature of the employer or the person who

29 CFR 1910.268(c)(3)

(3) First aid training, including instruction in artificial respiration.

29 CFR 1910.268(j)(4)(i)

(4) Derrick trucks and similar equipment. (i) This equipment shall not be operated with any conductive part of the equipment closer to exposed energized power lines than the clearances set forth in Table R-2 of this section.

Other power and communication line and related structures construction employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.