OSHA SearchOSHA records by employer

Reell Precision Manufacturing Corporation: OSHA inspections and violations

Vadnais Heights, Minnesota · Mechanical Power Transmission Equipment Manufacturing · NAICS 333613

11inspections
17citation items
$5,495current penalties
Aug 13, 2025last inspection

Since 1985, OSHA inspectors have visited Reell Precision Manufacturing Corporation in Minnesota 11 times.

The most recent inspection opened on Aug 13, 2025 as a planned inspection, in White Bear Lake.

In all, OSHA issued 17 citation items: 8 serious and 9 other-than-serious.

The proposed penalties came to $7,850; today they stand at $5,495, 30% less.

The rule cited most here is 1910.147 (lockout/tagout), 3 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Reell Precision Manufacturing Corporation averages $105 across 1 cited inspection.

Reell Precision Manufacturing Corporation: OSHA citation items per year, 1985 to 2025
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

375employers cited

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch Reell Precision Manufacturing Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348439332 OPENED AUG 13, 2025Closed

Planned · No inspection · Safety · 125 employees at the site · Closed Aug 19, 2025

1259 Willow Lake Blvd, White Bear Lake, MN 55110 · Mechanical Power Transmission Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345347454 OPENED JUN 7, 2021Closed

Planned · Complete · Safety · 125 employees at the site · Closed Jun 10, 2021

1259 Willow Lake Blvd, White Bear Lake, MN 55110 · Mechanical Power Transmission Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342150851 OPENED MAR 3, 2017Closed

Planned · Complete · Safety · 110 employees at the site · Closed Apr 5, 2017

1259 Willow Lake Blvd, White Bear Lake, MN 55110 · Mechanical Power Transmission Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(d)(1)(ii) · Ladders in general industry
Other-than-serious$150$105Mar 14, 2017Final

Inspection 316471127 OPENED APR 12, 2012Closed

Planned · Complete · Health · 110 employees at the site · Closed May 23, 2012

1259 Willow Lake Blvd, Vadnais Heights, MN 55127 · Mechanical Power Transmission Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1030(c)(1)(i) · Bloodborne pathogens
Serious$600$420May 7, 2012Closed
Citation 1, item 2
29 CFR 1910.1030(g)(2)(iib) · Bloodborne pathogens
Serious$600$420May 7, 2012Closed
Citation 2, item 1 Other-than-serious$400$280May 7, 2012Closed

Inspection 314066135 OPENED JAN 4, 2010Closed

Planned · Complete · Safety · 103 employees at the site · Closed Feb 8, 2010

1259 Willow Lake Blvd, St Paul, MN 55110 · Mechanical Power Transmission Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$600$420Jan 13, 2010Closed
Citation 2, item 1
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$150$105Jan 13, 2010Closed
Citation 2, item 2 Other-than-serious$150$105Jan 13, 2010Closed

Inspection 308723147 OPENED MAR 10, 2005Closed

Follow-up · Partial · Safety · 205 employees at the site · Closed Mar 23, 2005

1259 Willow Lake Blvd, White Bear Lake, MN 55110 · Mechanical Power Transmission Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 308634229 OPENED JAN 25, 2005Closed

Planned · Complete · Safety · 205 employees at the site · Closed Jul 11, 2005

1259 Willow Lake Blvd, White Bear Lake, MN 55110 · Mechanical Power Transmission Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$1,200$840Feb 8, 2005Closed
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,800$1,260Feb 8, 2005Closed
Citation 2, item 1 Other-than-serious$600$420Feb 8, 2005Closed

Inspection 302092473 OPENED JUL 31, 1998Closed

Planned · Complete · Safety · 140 employees at the site · Closed Sep 23, 1998

1259 Wolters Blvd., Vadnais Heights, MN 55110 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$0$0Aug 28, 1998Closed
Citation 1, item 2
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$800$560Aug 28, 1998Closed
Citation 1, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Serious$800$560Aug 28, 1998Closed
3 older inspections

Inspection 120375126 OPENED MAR 15, 1994Closed

Planned · Complete · Safety · 110 employees at the site · Closed Jun 2, 1994

1259 Wolters Blvd., Vadnais Heights, MN 55110 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Other-than-serious$0$0May 4, 1994Closed
Citation 1, item 2
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Other-than-serious$0$0May 4, 1994Closed
Citation 1, item 3
29 CFR 1910.305(g)(1)(iiia) · Electrical wiring methods
Other-than-serious$0$0May 4, 1994Closed
Citation 1, item 4 Other-than-serious$0$0May 4, 1994Closed

Inspection 107778300 OPENED MAY 10, 1988Closed

Planned · Complete · Safety · 42 employees at the site · Closed May 16, 1988

1259 Wolters Blvd., Vadnais Heights, MN 55110 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 2890465 OPENED AUG 29, 1985Closed

Planned · Records only · Safety · 42 employees at the site · Closed Sep 4, 1985

1259 Wolters Blvd, Vadnais Heights, MN 55110 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1820.6530

29 CFR 1910.1030 · Bloodborne pathogens

29 CFR 1910.1030(c)(1)(i)

(c) Exposure control—(1) Exposure Control Plan. (i) Each employer having an employee(s) with occupational exposure as defined by paragraph (b) of this section shall establish a written Exposure Control Plan designed to eliminate or minimize employee exposure.

29 CFR 1910.1030(g)(2)(iib)

(B) At least annually thereafter.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.23 · Ladders in general industry

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 5205.1200

29 CFR 5205.710

29 CFR 5206.700

Other mechanical power transmission equipment manufacturing employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.