OSHA SearchOSHA records by employer

Rehab Builders, Inc.: OSHA inspections and violations

Danville, Virginia · New Multifamily Housing Construction (except For-Sale Builders) · NAICS 236116

9inspections
17citation items
$26,714current penalties
Jul 15, 2025last inspection

OSHA has inspected Rehab Builders, Inc. 9 times in Virginia since 2006.

The latest one began on Jul 15, 2025 as part of a related case, in Danville.

Those inspections ended with 17 citation items: 15 serious and 2 other-than-serious.

Penalties were first proposed at $42,265 and now stand at $26,714, 37% lower after settlements or reviews.

Fall protection in construction comes up most often in these citations: 6 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Rehab Builders, Inc. averages $8,730 (3 cited inspections).

Rehab Builders, Inc.: OSHA citation items per year, 2006 to 2025
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

246employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Rehab Builders, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348372822 OPENED JUL 15, 2025Closed

Unprogrammed related · Partial · Safety · 3 employees at the site · Closed Oct 3, 2025

424 Memorial Drive, Danville, VA 24541 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$9,525$6,667Sep 4, 2025Final

Inspection 346896129 OPENED AUG 9, 2023Closed

Planned · Complete · Safety · 8 employees at the site · Closed Nov 20, 2023

424 Memorial Drive, Danville, VA 24541 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(b)(1) · Electrical equipment on job sites
Serious$3,250$2,275Oct 17, 2023Final
Citation 1, item 2
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$3,250$2,275Oct 17, 2023Final
Citation 1, item 3
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$3,250$2,275Oct 17, 2023Final
Citation 1, item 4
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Serious$3,250$2,275Oct 17, 2023Final
Citation 1, item 5
29 CFR 1926.501(b)(14) · Fall protection in construction
Serious$3,250$2,275Oct 17, 2023Final
Citation 1, item 6
29 CFR 1926.1052(c)(1) · Stairways in construction
Serious$1,700$1,190Oct 17, 2023Final
Citation 2, item 1
29 CFR 1926.150(c)(1)(viii) · Fire protection
Other-than-serious$0$0Oct 17, 2023Final
Citation 2, item 2
29 CFR 1926.1053(b)(16) · Ladders in construction
Other-than-serious$0$0Oct 17, 2023Final

Inspection 346024482 OPENED JUN 16, 2022Closed

Planned · Partial · Safety · 2 employees at the site · Closed Sep 28, 2022

Brook Villa 7800 Villa Park Drive, Henrico, VA 23228 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344699673 OPENED MAR 10, 2020Closed

Unprogrammed other · Partial · Safety · 3 employees at the site · Closed Jul 31, 2020

101 Aero Circle, Hampton, VA 23665 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.25(a) · Housekeeping
Serious$4,200$2,100May 7, 2020Final
Citation 1, item 2a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$4,200$2,100May 7, 2020Final
Citation 1, item 2b
29 CFR 1926.452(a)(2) · Rules for each type of scaffold
Serious$0$0May 7, 2020Final
Citation 1, item 2c
29 CFR 1926.452(a)(3) · Rules for each type of scaffold
Serious$0$0May 7, 2020Final
Citation 1, item 2d
29 CFR 1926.452(a)(4) · Rules for each type of scaffold
Serious$0$0May 7, 2020Final
Citation 1, item 2e
29 CFR 1926.452(a)(7) · Rules for each type of scaffold
Serious$0$0May 7, 2020Final
Citation 1, item 3
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$5,515$2,758May 7, 2020Final

Inspection 341537579 OPENED JUN 9, 2016Closed

Unprogrammed other · Complete · Safety · 50 employees at the site · Closed Jun 9, 2016

3000 Warwick Blvd, Newport News, VA 23607 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 317755536 OPENED JUN 4, 2014Closed

Planned · Partial · Safety · 7 employees at the site · Closed Jun 10, 2014

545 Bridge St, Danville, VA 24541 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311492912 OPENED NOV 27, 2007Closed

Planned · Partial · Safety · 4 employees at the site · Closed Nov 27, 2007

2 Heritage Drive, Bristol, VA 24201 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311289391 OPENED JUL 11, 2007Closed

Planned · Partial · Safety · 4 employees at the site · Closed Nov 26, 2007

2 Heritage Drive, Bristol, VA 24201 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(14) · Fall protection in construction
Serious$875$525Oct 30, 2007Closed
1 older inspection

Inspection 309956977 OPENED APR 12, 2006Closed

Planned · Partial · Safety · 24 employees at the site · Closed Apr 21, 2006

1201 Main Street, Lynchburg, VA 24504 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)

(1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with:

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(viii)

(viii) Portable fire extinguishers shall be inspected periodically and maintained in accordance with Maintenance and Use of Portable Fire Extinguishers, NFPA No. 10A-1970.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.501 · Fall protection in construction

Other new multifamily housing construction (except for-sale builders) employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.