Reich Installation Services, Inc. has one OSHA inspection on record in Georgia.

OSHA opened it on Dec 9, 2015 after a fatality or catastrophe, in Forest Park.

From that inspection OSHA issued 4 citation items: 4 serious.

OSHA proposed $121,800 in penalties. After settlements and reviews the total is $49,500, down 59%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Reich Installation Services, Inc. averages $49,500 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

Reich Installation Services, Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

148employers cited

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Reich Installation Services, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Company-wide record

OSHA records show Reich Installation Services, Inc. at 2 sites in 2 states. Together they've had 2 inspections and $52,600 in current penalties.

We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.

Included with any plan: the site-by-site record for all 2 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.

See plans

Inspection history

Inspection 341143584 OPENED DEC 9, 2015Closed

Fatality or catastrophe · Partial · Safety · 55 employees at the site · Closed Jul 18, 2017

2000 Anvil Block Road, Forest Park, GA 30297 · Other Building Equipment Contractors · OSHA's record · Phone and website on Google Maps

Incident on Dec 8, 2015 (fatal): Employee falls from swing-stage scaffold and is killed

At 5:30 p.m. on December 8, 2015, two employees were ascending on a swing-stage scaffold to inspect the I-beam supporting the scaffold system. The Company's Safety Manager asked the employees to ascend on the swing-stage scaffold to inspect and adjust the I-beam supporting the scaffold system. The Safety Manager made the request after they attempted to move the swing-stage scaffold from the ground and one of the I-beam trolleys being used to support the scaffold system and lifelines became stuck. The I-beam supporting the swing-stage scaffold was part of a High Bay Pallet Storage (HBPS) system upper guide rail. The upper guide rail supporting the swing-stage scaffold was designed to keep the HBPS system crane plumbed during operation and not designed as a load bearing I-beam. The upper rail was approximately 76 feet, 9 inches above ground level and consisted of sixteen I-beam sections. Trolley anchors were used to connect the Spider swing-stage scaffold system to the I-beam. The upper guide rail I-beam was connected and supported by cross aisle ties (CATs). It was established during the investigation, the weight of the scaffold system and the I-beam exceeded the CAT's maximum intended load capacity. At the time of the accident, the upper guide rail (I-beam) sections were not connected and had visible gaps between the rail joints. The Safety Manager and scaffold competent person did not perform a visual inspection of the upper guide rail prior to using the scaffold. The rail sections gap increased as a result of the CAT deflection due to the imposed load. The gaps allowed three (3) I-beam rollers to roll off the I-beam causing the employee to fall approximately 40 feet to the next lower level. The employee received multiple internal injuries resulting from a forty (40) foot fall and being struck by the swing-stage scaffold which also fell from a height of approximately forty (40) feet, and was killed. The employee was fatally injured when a Spider swing-stage scaffold fell approximately 40 feet to the next lower level. A second employee was left suspended from his lifeline and suffered minor injuries. suffered minor injuries.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(3) · Scaffolds, general requirements
Serious$4,900$12,471Jun 7, 2016Final
Citation 1, item 2
29 CFR 1926.454(b) · Scaffold training
Serious$4,900$12,087Jun 7, 2016Final
Citation 2, item 1
29 CFR 1926.451(f)(1) · Scaffolds, general requirements
Serious$56,000$12,471Jun 7, 2016Final
Citation 2, item 2
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$56,000$12,471Jun 7, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(1)

(f) Use. (1) Scaffolds and scaffold components shall not be loaded in excess of their maximum intended loads or rated capacities, whichever is less.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.451(g)(3)

(3) In addition to meeting the requirements of § 1926.502(d), personal fall arrest systems used on scaffolds shall be attached by lanyard to a vertical lifeline, horizontal lifeline, or scaffold structural member. Vertical lifelines shall not be used when overhead components, such as overhead protection or additional platform levels, are part of a single-point or two-point adjustable suspension scaffold.

29 CFR 1926.454 · Scaffold training