OSHA SearchOSHA records by employer

Reliable Installation Services LLC: OSHA inspections and violations

Baltimore, Maryland · Roofing Contractors · NAICS 238160

2inspections
3citation items
$729current penalties
Oct 29, 2019last inspection

Since 2018, OSHA inspectors have visited Reliable Installation Services LLC in Maryland 2 times.

The most recent inspection opened on Oct 29, 2019 as a planned inspection, in Rockville.

In all, OSHA issued 3 citation items: 1 serious and 2 other-than-serious.

The proposed penalties came to $1,350; today they stand at $729, 46% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Reliable Installation Services LLC averages $364 across 2 cited inspections.

Reliable Installation Services LLC: OSHA citation items per year, 2018 to 2019
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

197employers cited

39 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Reliable Installation Services LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344416763 OPENED OCT 29, 2019Closed

Planned · Complete · Safety · 11 employees at the site · Closed Feb 24, 2020

909 & 911 Prose Street, Rockville, MD 20852 · Glass and Glazing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.502(b)(3) · Fall protection systems
Other-than-serious$0$0Jan 23, 2020Final
Citation 1, item 2
29 CFR 1926.1052(c)(1)(i) · Stairways in construction
Other-than-serious$0$0Jan 23, 2020Final

Inspection 343255071 OPENED JUN 25, 2018Closed

Unprogrammed related · Partial · Safety · 7 employees at the site · Closed Dec 12, 2018

2500 W. North Avenue, Baltimore, MD 21216 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$1,350$729Oct 30, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)(i)

(i) At least one handrail; and

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(4)(i)

(4) Holes. (i) Each employee on walking/working surfaces shall be protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes.

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.502(b)(3)

(3) Guardrail systems shall be capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge.