OSHA SearchOSHA records by employer

Rene Perez Barrera: OSHA inspections and violations

Edinburg, Texas · Masonry Contractors · NAICS 238140

1inspections
5citation items
$1,108current penalties
Jan 26, 2017last inspection

OSHA inspectors have visited Rene Perez Barrera in Texas one time.

It opened on Jan 26, 2017 as a planned inspection, in Edinburg.

In all, OSHA issued 5 citation items: 5 serious.

The proposed penalties came to $1,847; today they stand at $1,108, 40% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 5 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Rene Perez Barrera averages $1,108 across 1 cited inspection.

Rene Perez Barrera: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Rene Perez Barrera and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342056587 OPENED JAN 26, 2017Closed

Planned · Partial · Safety · 10 employees at the site · Closed Apr 5, 2017

2501 Vancouver Ave., Edinburg, TX 78539 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$1,847$1,108Mar 17, 2017Final
Citation 1, item 1b
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Mar 17, 2017Final
Citation 1, item 1c
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Mar 17, 2017Final
Citation 1, item 1d
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$0$0Mar 17, 2017Final
Citation 1, item 1e
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Mar 17, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

Other masonry contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.