OSHA SearchOSHA records by employer

Reye's Construction Group LLC: OSHA inspections and violations

Rockville, Maryland · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

1inspections
6citation items
$7,200current penalties
Jul 21, 2022last inspection

OSHA has inspected Reye's Construction Group LLC once in Maryland.

The inspection began on Jul 21, 2022 after an accident, in Rockville; the case is still open.

That inspection ended with 6 citation items: 6 serious.

Penalties were first proposed at $7,200 and still stand at $7,200.

Excavations comes up most often in these citations: 4 items under 1926.651.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Reye's Construction Group LLC averages $7,200 (1 cited inspection).

Reye's Construction Group LLC: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

194employers cited

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Reye's Construction Group LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346094535 OPENED JUL 21, 2022Open

Accident · Partial · Safety · 3 employees at the site · Open

9608 Veirs Drive, Rockville, MD 20850 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Serious$2,050$2,050Dec 5, 2022Final
Citation 1, item 2a
29 CFR 1926.651(b)(2) · Excavations
Serious$1,050$1,050Dec 5, 2022Final
Citation 1, item 2b
29 CFR 1926.651(c)(2) · Excavations
Serious$0$0Dec 5, 2022Final
Citation 1, item 2c
29 CFR 1926.651(h)(1) · Excavations
Serious$0$0Dec 5, 2022Final
Citation 1, item 3
29 CFR 1926.651(k)(1) · Excavations
Serious$2,050$2,050Dec 5, 2022Final
Citation 1, item 4
29 CFR 1926.652(a)(1) · Trench protection
Serious$2,050$2,050Dec 5, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(b)(2)

(2) Utility companies or owners shall be contacted within established or customary local response times, advised of the proposed work, and asked to establish the location of the utility underground installations prior to the start of actual excavation. When utility companies or owners cannot respond to a request to locate underground utility installations within 24 hours (unless a longer period is required by state or local law), or cannot establish the exact location of these installations, the employer may proceed, provided the employer does so with caution, and provided detection equipment or other acceptable means to locate utility installations are used.

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.652 · Trench protection

Other new single-family housing construction (except for-sale builders) employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.