OSHA SearchOSHA records by employer

Reyes Masonry LLC: OSHA inspections and violations

Rockwall, Texas · Masonry Contractors · NAICS 238140

1inspections
6citation items
$21,988current penalties
May 14, 2025last inspection

OSHA has inspected Reyes Masonry LLC once in Texas.

The inspection began on May 14, 2025 after a fatality or catastrophe, in Rockwall; the case is still open.

That inspection ended with 6 citation items: 6 serious.

Penalties were first proposed at $21,988 and still stand at $21,988.

Scaffolds, general requirements comes up most often in these citations: 5 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Reyes Masonry LLC averages $21,988 (1 cited inspection).

Reyes Masonry LLC: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Reyes Masonry LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348248543 OPENED MAY 14, 2025Open

Fatality or catastrophe · Partial · Safety · 7 employees at the site · Open

607 White Hills Drive, Rockwall, TX 75032 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$4,965$4,965Nov 10, 2025Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$4,965$4,965Nov 10, 2025Final
Citation 1, item 3
29 CFR 1926.451(f)(6) · Scaffolds, general requirements
Serious$4,965$4,965Nov 10, 2025Final
Citation 1, item 4a
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$2,128$2,128Nov 10, 2025Final
Citation 1, item 4b
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Nov 10, 2025Final
Citation 1, item 5
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$4,965$4,965Nov 10, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(f)(6)

(6) The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows:

29 CFR 1926.454 · Scaffold training