OSHA SearchOSHA records by employer

Reynaldo Felipe Coto Ramos: OSHA inspections and violations

Manvel, Texas · Masonry Contractors · NAICS 238140

3inspections
10citation items
$28,803current penalties
Oct 3, 2022last inspection

Reynaldo Felipe Coto Ramos has 3 OSHA inspections on record in Texas, the first in 2013.

OSHA's last visit started on Oct 3, 2022 as a planned inspection, in Flower Mound.

Across those inspections OSHA issued 10 citation items: 7 serious, 2 repeat and 1 other-than-serious.

OSHA proposed $28,803 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (6 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Reynaldo Felipe Coto Ramos averages $14,402 over 2 cited inspections in that time.

Reynaldo Felipe Coto Ramos: OSHA citation items per year, 2013 to 2022
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

405employers cited

12 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Reynaldo Felipe Coto Ramos and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346260482 OPENED OCT 3, 2022Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jun 4, 2025

301 International Parkway, Flower Mound, TX 75027 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$3,108$3,108Oct 28, 2022Final

Inspection 342284395 OPENED APR 27, 2017Closed

Planned · Partial · Safety · 3 employees at the site · Closed Aug 18, 2022

2111 North St., Nacogdoches, TX 75965 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$1,793$1,793May 23, 2017Final
Citation 1, item 2a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$3,585$3,585May 23, 2017Final
Citation 1, item 2b
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$0$0May 23, 2017Final
Citation 1, item 3a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$2,988$2,988May 23, 2017Final
Citation 1, item 3b
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$0$0May 23, 2017Final
Citation 1, item 4
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$1,793$1,793May 23, 2017Final
Citation 2, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Repeat$7,170$7,170May 23, 2017Final
Citation 2, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Repeat$8,366$8,366May 23, 2017Final
Citation 3, item 1
29 CFR 1926.1053(b)(4) · Ladders in construction
Other-than-serious$0$0May 23, 2017Final

Inspection 339098410 OPENED JUN 4, 2013Closed

Planned · Complete · Safety · 10 employees at the site · Closed Mar 25, 2020

17502 Hwy 6, Manvel, TX 77578 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.453 · Aerial lifts

Other masonry contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.