OSHA SearchOSHA records by employer

RFX2024XT3633X0167 - Reddy Ice LLC: OSHA inspections and violations

Phoenix, Arizona · Ice Manufacturing · NAICS 312113

1inspections
4citation items
$8,296current penalties
Jun 10, 2024last inspection

OSHA has inspected RFX2024XT3633X0167 - Reddy Ice LLC once in Arizona.

The inspection began on Jun 10, 2024 on a referral, in Phoenix; the case is still open.

That inspection ended with 4 citation items: 2 serious and 2 other-than-serious.

Penalties were first proposed at $8,296 and still stand at $8,296.

Electrical wiring methods comes up most often in these citations: 2 items under 1910.305.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,872, and RFX2024XT3633X0167 - Reddy Ice LLC averages $8,296 (1 cited inspection).

RFX2024XT3633X0167 - Reddy Ice LLC: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Arizona · latest 90 days of OSHA records

84employers cited

Get notified the morning OSHA posts each new citation in Arizona: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Arizona

Checking a subcontractor, a client or your own company? Watch RFX2024XT3633X0167 - Reddy Ice LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347547333 OPENED JUN 10, 2024Open

Referral · Partial · Health · 70 employees at the site · Open

4626 S 40th St, Phoenix, AZ 85040 · Ice Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$8,296$8,296Nov 14, 2024Final
Citation 1, item 1b
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$0$0Nov 14, 2024Final
Citation 2, item 1
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Nov 14, 2024Final
Citation 2, item 2
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Nov 14, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.219(e)(1)(i)

(e) Belt, rope, and chain drives—(1) Horizontal belts and ropes. (i) Where both runs of horizontal belts are seven (7) feet or less from the floor level, the guard shall extend to at least fifteen (15) inches above the belt or to a standard height except that where both runs of a horizontal belt are 42 inches or less from the floor, the belt shall be fully enclosed in accordance with paragraphs (m) and (o) of this section.

29 CFR 1910.219(f)(3)

(3) Sprockets and chains. All sprocket wheels and chains shall be enclosed unless they are more than seven (7) feet above the floor or platform. Where the drive extends over other machine or working areas, protection against falling shall be provided. This subparagraph does not apply to manually operated sprockets.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(2)(i)

(2) Covers and canopies. (i) All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

Other ice manufacturing employers in Arizona

Alert subscribers get notified of each newly cited employer in Arizona the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.