OSHA SearchOSHA records by employer

RG Steel Erectors, LLC: OSHA inspections and violations

Covington, Louisiana · Structural Steel and Precast Concrete Contractors · NAICS 238120

1inspections
3citation items
$8,511current penalties
Oct 28, 2024last inspection

OSHA inspectors have visited RG Steel Erectors, LLC in Louisiana one time.

It opened on Oct 28, 2024 as a planned inspection, in Covington and is still open.

In all, OSHA issued 3 citation items: 3 serious.

The penalties, $8,511 in total, stand where OSHA first set them.

The rule cited most here is 1926.760 (fall protection), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. RG Steel Erectors, LLC averages $8,511 across 1 cited inspection.

RG Steel Erectors, LLC: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Louisiana · latest 90 days of OSHA records

18employers cited

Get notified the morning OSHA posts each new citation in Louisiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Louisiana

Checking a subcontractor, a client or your own company? Watch RG Steel Erectors, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347844458 OPENED OCT 28, 2024Open

Planned · Partial · Safety · 3 employees at the site · Open

7409 Pinnacle Pkwy, Covington, LA 70433 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$2,837$2,837Feb 4, 2025Final
Citation 1, item 2
29 CFR 1926.760(a)(1) · Fall protection
Serious$2,837$2,837Feb 4, 2025Final
Citation 1, item 3
29 CFR 1926.760(c)(3) · Fall protection
Serious$2,837$2,837Feb 4, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.453(b)(2)(v)

(v) A body belt shall be worn and a lanyard attached to the boom or basket when working from an aerial lift.

29 CFR 1926.760 · Fall protection

29 CFR 1926.760(a)(1)

(a) General requirements. (1) Except as provided by paragraph (a)(3) of this section, each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level shall be protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems or fall restraint systems.

29 CFR 1926.760(c)(3)

(3) The boundaries of a CDZ shall be designated and clearly marked. The CDZ shall not be more than 90 feet (27.4 m) wide and 90 (27.4 m) feet deep from any leading edge. The CDZ shall be marked by the use of control lines or the equivalent. Examples of acceptable procedures for demarcating CDZ's can be found in appendix D to this subpart.

Other structural steel and precast concrete contractors employers in Louisiana

Alert subscribers get notified of each newly cited employer in Louisiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.