OSHA SearchOSHA records by employer

RHG Manpower Inc: OSHA inspections and violations

New York, New York · Temporary Help Services · NAICS 561320

1inspections
3citation items
$14,000current penalties
Jun 21, 2019last inspection

OSHA has inspected RHG Manpower Inc once in New York.

The inspection began on Jun 21, 2019 as a planned inspection, in New York.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $22,542 and now stand at $14,000, 38% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for staffing, cleaning and waste services employers since 2015 is $2,217, and RHG Manpower Inc averages $14,000 (1 cited inspection).

RHG Manpower Inc: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

362employers cited

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch RHG Manpower Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344102447 OPENED JUN 21, 2019Closed

Planned · Partial · Safety · 5 employees at the site · Closed Dec 31, 2020

233 Spring Street, New York, NY 10014 · Temporary Help Services · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$6,630$3,783Nov 21, 2019Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$6,630$3,783Nov 21, 2019Final
Citation 1, item 3
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$9,282$6,434Nov 21, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

Other temporary help services employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.