OSHA SearchOSHA records by employer

Ricardo Sanchez: OSHA inspections and violations

Dallas, Texas · Siding Contractors · NAICS 238170

2inspections
7citation items
$19,559current penalties
Oct 2, 2020last inspection

Ricardo Sanchez has 2 OSHA inspections on record in Texas, the first in 2019.

OSHA's last visit started on Oct 2, 2020 as a planned inspection, in Mansfield.

Across those inspections OSHA issued 7 citation items: 6 serious and 1 repeat.

OSHA proposed $29,271 in penalties. After settlements and reviews the total is $19,559, down 33%.

Most often, OSHA cited 1926.501, fall protection in construction (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Ricardo Sanchez averages $9,780 over 2 cited inspections in that time.

1 inspection on this page followed a fatal incident.

Ricardo Sanchez: OSHA citation items per year, 2019 to 2020
Citation items per year, by inspection date.

Want to know if OSHA cites Ricardo Sanchez again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344956529 OPENED OCT 2, 2020Closed

Planned · Partial · Safety · 2 employees at the site · Closed Mar 20, 2024

7594 Remington Road, Mansfield, TX 76063 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$4,453$4,453Nov 17, 2020Final
Citation 2, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$8,906$8,906Nov 17, 2020Final

Inspection 344133673 OPENED JUL 5, 2019Closed

Fatality or catastrophe · Partial · Safety · 3 employees at the site · Closed Jun 18, 2020

7006 Briar Cove Drive, Dallas, TX 75354 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jul 5, 2019 (fatal): Employee working near overhead power line is electrocuted

At 10:00 a.m. on July 5, 2019, Employee #1 was working at a two-story building, a multiemployer construction project. He was working from an extension ladder and detaching a gutter when the detached gutter came into contact with an overhead power line. Employee #1 was electrocuted.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$3,978$1,550Nov 22, 2019Final
Citation 1, item 1b
29 CFR 1926.416(a)(3) · Electrical safety in construction
Serious$0$0Nov 22, 2019Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,978$1,550Nov 22, 2019Final
Citation 1, item 3
29 CFR 1926.1053(b)(12) · Ladders in construction
Serious$3,978$1,550Nov 22, 2019Final
Citation 1, item 4
29 CFR 1926.1060(a) · Ladder and stairway training
Serious$3,978$1,550Nov 22, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(12)

(12) Ladders shall have nonconductive siderails if they are used where the employee or the ladder could contact exposed energized electrical equipment, except as provided in § 1926.955(b) and (c) of this part.

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.1060(a)

(a) The employer shall provide a training program for each employee using ladders and stairways, as necessary. The program shall enable each employee to recognize hazards related to ladders and stairways, and shall train each employee in the procedures to be followed to minimize these hazards.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.501 · Fall protection in construction

Other siding contractors employers in Texas