Inspection 342500683 OPENED JUL 26, 2017Closed
4106 Howley Street, Pittsburgh, PA 15224 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Pittsburgh, Pennsylvania · Masonry Contractors · NAICS 238140
Since 2013, OSHA inspectors have visited Richard Roth in Pennsylvania 3 times.
The most recent inspection opened on Jul 26, 2017 to follow up on an earlier case, in Pittsburgh.
In all, OSHA issued 16 citation items: 14 serious and 2 repeat.
The penalties, $30,528 in total, stand where OSHA first set them.
The rule cited most here is 1926.451 (scaffolds, general requirements), 12 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Richard Roth averages $21,728 across 1 cited inspection.
Pennsylvania · latest 90 days of OSHA records
297employers cited
8 of them in the same industry
Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Pennsylvania
Checking a subcontractor, a client or your own company? Watch Richard Roth and get notified the morning OSHA posts a new citation for it.
Watch this company4106 Howley Street, Pittsburgh, PA 15224 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
At/near 4106 Howley Street, Pittsburgh, PA 15224 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.451(c)(1) · Scaffolds, general requirements |
Serious | $2,716 | $2,716 | Mar 31, 2017 | Final |
| Citation 1, item 1b 29 CFR 1926.451(c)(2) · Scaffolds, general requirements |
Serious | $0 | $0 | Mar 31, 2017 | Final |
| Citation 1, item 1c 29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements |
Serious | $0 | $0 | Mar 31, 2017 | Final |
| Citation 1, item 2 29 CFR 1926.451(f)(6) · Scaffolds, general requirements |
Serious | $2,716 | $2,716 | Mar 31, 2017 | Final |
| Citation 1, item 3 29 CFR 1926.501(b)(1) · Fall protection in construction |
Serious | $2,716 | $2,716 | Mar 31, 2017 | Final |
| Citation 1, item 4 29 CFR 1926.503(a)(1) · Fall protection training in construction |
Serious | $2,716 | $2,716 | Mar 31, 2017 | Final |
| Citation 2, item 1 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Repeat | $5,432 | $5,432 | Mar 31, 2017 | Final |
| Citation 2, item 2 29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements |
Repeat | $5,432 | $5,432 | Mar 31, 2017 | Final |
318 45th Street, Pittsburgh, PA 15201 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.100(a) · Hard hats in construction |
Serious | $1,600 | $1,600 | Jun 10, 2013 | Final |
| Citation 1, item 2a 29 CFR 1926.451(b)(1) · Scaffolds, general requirements |
Serious | $1,600 | $1,600 | Jun 10, 2013 | Final |
| Citation 1, item 2b 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $0 | $0 | Jun 10, 2013 | Final |
| Citation 1, item 2c 29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements |
Serious | $0 | $0 | Jun 10, 2013 | Final |
| Citation 1, item 2d 29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements |
Serious | $0 | $0 | Jun 10, 2013 | Final |
| Citation 1, item 3 29 CFR 1926.451(f)(3) · Scaffolds, general requirements |
Serious | $1,600 | $1,600 | Jun 10, 2013 | Final |
| Citation 1, item 4 29 CFR 1926.451(g)(1)(i) · Scaffolds, general requirements |
Serious | $2,400 | $2,400 | Jun 10, 2013 | Final |
| Citation 1, item 5 29 CFR 1926.454(a) · Scaffold training |
Serious | $1,600 | $1,600 | Jun 10, 2013 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.100(a)
(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.
29 CFR 1926.451(b)(1)
(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:
29 CFR 1926.451(c)(1)
(c) Criteria for supported scaffolds. (1) Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means, as follows:
Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.