OSHA SearchOSHA records by employer

Richard S. Espinoza: OSHA inspections and violations

Houston, Texas · Wood Kitchen Cabinet and Countertop Manufacturing · NAICS 337110

1inspections
3citation items
$5,266current penalties
May 16, 2018last inspection

OSHA has inspected Richard S. Espinoza once in Texas.

The inspection began on May 16, 2018 after a complaint, in Houston.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $10,532 and now stand at $5,266, 50% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Richard S. Espinoza averages $5,266 (1 cited inspection).

Richard S. Espinoza: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Richard S. Espinoza and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343167292 OPENED MAY 16, 2018Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Nov 30, 2020

7409a Wright Road, Houston, TX 77041 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$2,772$1,386Jun 6, 2018Final
Citation 1, item 2
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Serious$3,880$1,940Jun 6, 2018Final
Citation 1, item 3
29 CFR 1910.305(d)(2) · Electrical wiring methods
Serious$3,880$1,940Jun 6, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(c)(1)

(c) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(g)(1)

(1) Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(d)(2)

(2) Panelboard enclosures. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons.

Other wood kitchen cabinet and countertop manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.