OSHA SearchOSHA records by employer

Ridgeway Plumbing Inc.: OSHA inspections and violations

Boca Raton, Florida · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

10inspections
16citation items
$5,292current penalties
Sep 12, 2025last inspection

Since 1981, OSHA inspectors have visited Ridgeway Plumbing Inc. in Florida 10 times.

The most recent inspection opened on Sep 12, 2025 as part of a related case, in Stuart.

In all, OSHA issued 16 citation items: 8 serious and 8 other-than-serious.

The proposed penalties came to $9,257; today they stand at $5,292, 43% less.

The rule cited most here is 1926.500 (scope, application, and definitions applicable to this subpart), 6 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Ridgeway Plumbing Inc. averages $3,377 across 1 cited inspection.

Ridgeway Plumbing Inc. also files yearly injury logs with OSHA, summarized below.

The Wage and Hour Division has 1 case on it since 2015, with $397 in back wages owed to workers.

Ridgeway Plumbing Inc.: OSHA citation items per year, 1981 to 2025
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

320employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Ridgeway Plumbing Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348503772 OPENED SEP 12, 2025Closed

Unprogrammed related · Partial · Safety · 50 employees at the site · Closed Mar 27, 2026

10291 Sw Highpointe, Stuart, FL 34997 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Other-than-serious$5,627$3,377Mar 9, 2026Final

Inspection 108995374 OPENED MAY 22, 1992Closed

Unprogrammed other · Complete · Safety · 10 employees at the site · Closed Aug 27, 1992

5200-5460 Nw 55 Blvd., Coconut Creek, FL 33063 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.500(b)(2) · Scope, application, and definitions applicable to this subpart
Serious$700$350Aug 13, 1992Closed
Citation 1, item 2
29 CFR 1926.1052(c)(1) · Stairways in construction
Serious$700$350Aug 13, 1992Closed
Citation 2, item 1
29 CFR 1926.500(d)(1) · Scope, application, and definitions applicable to this subpart
Other-than-serious$0$0Aug 13, 1992Closed
Citation 2, item 2
29 CFR 1926.1053(b)(8) · Ladders in construction
Other-than-serious$0$0Aug 13, 1992Closed

Inspection 106110737 OPENED FEB 7, 1991Closed

Unprogrammed other · Complete · Safety · 4 employees at the site · Closed May 22, 1991

948 Victoria Lake Dr. #b, West Palm Beach, FL 33411 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 110051950 OPENED DEC 7, 1990Closed

Unprogrammed related · Complete · Safety · 6 employees at the site · Closed Mar 20, 1991

9601 Boynton Beach Blvd., Boynton Beach, FL 33435 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.25(a) · Housekeeping
Serious$420$210Feb 8, 1991Closed
Citation 1, item 2
29 CFR 1926.500(b)(1) · Scope, application, and definitions applicable to this subpart
Serious$350$175Feb 8, 1991Closed
Citation 1, item 3
29 CFR 1926.500(d)(1) · Scope, application, and definitions applicable to this subpart
Serious$420$210Feb 8, 1991Closed
Citation 1, item 4
29 CFR 1926.500(e)(1)(ii) · Scope, application, and definitions applicable to this subpart
Serious$420$210Feb 8, 1991Closed

Inspection 18292276 OPENED OCT 17, 1989Closed

Unprogrammed related · Complete · Safety · 10 employees at the site · Closed Nov 22, 1989

4000 Rca Blvd., Palm Beach Garden, FL 33410 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.59(e)(1) · Hazard communication
Other-than-serious$0$0Nov 6, 1989Closed
Citation 1, item 1b
29 CFR 1926.59(g)(8) · Hazard communication
Other-than-serious$0$0Nov 6, 1989Closed
Citation 1, item 1c
29 CFR 1926.59(h) · Hazard communication
Other-than-serious$0$0Nov 6, 1989Closed

Inspection 100370899 OPENED NOV 17, 1986Closed

Unprogrammed related · Complete · Safety · 8 employees at the site · Closed Nov 19, 1986

7579 Imperial Dr., Boca Raton, FL 33433 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 1206465 OPENED FEB 26, 1985Closed

Planned · Complete · Safety · 8 employees at the site · Closed Mar 7, 1985

3900 Washington Road, West Palm Beach, FL 33406 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 1655349 OPENED JUN 20, 1984Closed

Referral · Complete · Safety · 16 employees at the site · Closed Jul 26, 1984

7171 Promenade Drive, Boca Raton, FL 33433 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.500(d)(2) · Scope, application, and definitions applicable to this subpart
Serious$420$210Jul 16, 1984Closed
Citation 2, item 1
29 CFR 1926.302(e)(1) · Power-operated hand tools
Other-than-serious$0$0Jul 16, 1984Closed
Citation 2, item 2
29 CFR 1926.401(f) · [Reserved]
Other-than-serious$0$0Jul 16, 1984Closed
2 older inspections

Inspection 1168368 OPENED JUN 7, 1984Closed

Planned · Complete · Safety · 10 employees at the site · Closed Jun 29, 1984

Edgewater Pointe Estates 23315 Bluewater Circle, Boca Raton, FL 33433 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 13464359 OPENED AUG 4, 1981Closed

Planned · Complete · Safety · 5 employees at the site · Closed Sep 22, 1981

2701 W Germantown Rd, Delray Beach, FL 33445 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(4) · Scaffolds, general requirements
Serious$200$200Aug 13, 1981Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Boynton Beach site logged 17 recordable injuries or illnesses among about 468 workers: 3.6 per 100 full-time workers, against a median of 1.8 for its industry. Those cases cost 9 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Ridgeway Plumbing, Inc.
Boynton Beach · 2025
468 1733.61.8

Included with any plan: 8 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Wage and hour cases

Cases by the Labor Department's Wage and Hour Division since 2015: unpaid minimum wage or overtime, child labor, family leave and more.

Period reviewedViolationsWorkers owedBack wagesPenalties
Oct 13, 2016 to Oct 12, 2018
Boynton Beach
82$397$0

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)

(1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with:

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(8)

(8) Ladders placed in any location where they can be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, shall be secured to prevent accidental displacement, or a barricade shall be used to keep the activities or traffic away from the ladder.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.302 · Power-operated hand tools

29 CFR 1926.401 · [Reserved]

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart

29 CFR 1926.59 · Hazard communication

Other plumbing, heating, and air-conditioning contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.