OSHA SearchOSHA records by employer

Riesbeck Contracting, Inc.: OSHA inspections and violations

Virginia Beach, Virginia · Commercial and Institutional Building Construction · NAICS 236220

4inspections
6citation items
$5,839current penalties
Jul 24, 2023last inspection

Since 2013, OSHA inspectors have visited Riesbeck Contracting, Inc. in Virginia 4 times.

The most recent inspection opened on Jul 24, 2023 after a complaint, in Hampton.

In all, OSHA issued 6 citation items: 6 serious.

The proposed penalties came to $8,342; today they stand at $5,839, 30% less.

The rule cited most here is 1926.651 (excavations), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Riesbeck Contracting, Inc. averages $4,369 across 1 cited inspection.

Riesbeck Contracting, Inc.: OSHA citation items per year, 2013 to 2023
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

249employers cited

21 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Riesbeck Contracting, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346858293 OPENED JUL 24, 2023Closed

Complaint · Partial · Health · 4 employees at the site · Closed Dec 21, 2023

1 Nasa Drive, Hampton, VA 23666 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345466783 OPENED AUG 6, 2021Closed

Referral · Partial · Safety · 13 employees at the site · Closed Nov 2, 2021

373 Bullpup Street Building 470 Rm. 218, Virginia Beach, VA 23461 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Serious$3,121$2,185Oct 4, 2021Final
Citation 1, item 2
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$3,121$2,185Oct 4, 2021Final

Inspection 344995386 OPENED OCT 22, 2020Closed

Planned · No inspection · Safety · Closed Oct 22, 2020

2420 Mattaponi Road, Virginia Beach, VA 23479 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 317487502 OPENED DEC 6, 2013Closed

Planned · Partial · Safety · 14 employees at the site · Closed Feb 10, 2014

2549 Sand Fiddler Road, Virginia Beach, VA 23456 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.651(k)(1) · Excavations
Serious$2,100$1,470Jan 16, 2014Closed
Citation 1, item 1b
29 CFR 1926.651(c)(2) · Excavations
Serious$0$0Jan 16, 2014Closed
Citation 1, item 1c
29 CFR 1926.651(j)(2) · Excavations
Serious$0$0Jan 16, 2014Closed
Citation 1, item 1d
29 CFR 1926.652(a)(1) · Trench protection
Serious$0$0Jan 16, 2014Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(i)(2)(i)

(2) Guarding of live parts. (i) Except as required or permitted elsewhere in this subpart, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by cabinets or other forms of enclosures, or by any of the following means:

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.652 · Trench protection

Other commercial and institutional building construction employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.