OSHA SearchOSHA records by employer

Right-Way Masonry, LLC: OSHA inspections and violations

Douglasville, Georgia · Masonry Contractors · NAICS 238140

1inspections
2citation items
$3,978current penalties
Aug 7, 2018last inspection

Right-Way Masonry, LLC has one OSHA inspection on record in Georgia.

OSHA opened it on Aug 7, 2018 as a planned inspection, in Douglasville.

From that inspection OSHA issued 2 citation items: 2 serious.

OSHA proposed $3,978 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Right-Way Masonry, LLC averages $3,978 over 1 cited inspection in that time.

Right-Way Masonry, LLC: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

147employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Right-Way Masonry, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343377107 OPENED AUG 7, 2018Closed

Planned · Partial · Safety · 3 employees at the site · Closed Jul 18, 2022

5888 Fairburn Rd., Douglasville, GA 30134 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$3,978$3,978Feb 1, 2019Final
Citation 1, item 1b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Feb 1, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.