Inspection 344489869 OPENED DEC 4, 2019Closed
Hannibal Bpw Granulary Activated Carbon Facility, Hannibal, MO 63401 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
River City Construction has 17 OSHA inspections on record in Missouri, the first in 2000.
OSHA's last visit started on Dec 4, 2019 as a planned inspection, in Hannibal.
Across those inspections OSHA issued 8 citation items: 2 serious and 6 other-than-serious.
OSHA proposed $20,950 in penalties. After settlements and reviews the total is $16,450, down 21%.
Most often, OSHA cited 1926.405, job-site wiring (2 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,079. River City Construction averages $9,500 over 1 cited inspection in that time.
1 inspection on this page followed a fatal incident.
Want to know if OSHA cites River City Construction again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this companyHannibal Bpw Granulary Activated Carbon Facility, Hannibal, MO 63401 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Marshall Missouri Water Treatment Plant 101 Hoffer Lane, Malta Bend, MO 65339 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
Incident on May 30, 2017 (fatal): Employee falls from elevation and is killed
At 12:30 p.m. on May 30, 2017, an employee was attempting to pull a steel mat back to the form so it could be tied into place. He had double wrapped the tie wire around the steel, and was using a 2 by 4 for leverage. He was tied off with one of his lanyards and his positioning hook. Both items were attached to the same location on the vertical bar beneath the first horizontal bar. The 2 by 4 snapped causing the employee to lose balance and fall backwards. The force from the board breaking and the employee falling backwards pulled upwards on the attachment point breaking the wires which were tied around the rebar. This forced the horizontal bar upward allowing the positioning hook and lanyard to slip off the vertical and horizontal steel rebar. The employee fell approximately 21 feet and was killed from head and internal injuries. internal injuries.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements |
Other-than-serious | $12,675 | $9,500 | Sep 18, 2017 | Final |
800 Hospital Drive, Columbia, MO 65201 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1310 South Florence, Kirksville, MO 63501 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
876 S. Davis Street, Kirksville, MO 63501 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Clarence Cannon Water Project, Stoutsville, MO 65283 · Other Heavy and Civil Engineering Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.652(a)(1) · Trench protection |
Other-than-serious | $1,625 | $975 | Aug 25, 2006 | Closed |
1703 East Broadway, Columbia, MO 65201 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
302 W. Normal, Kirksville, MO 63501 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
6851 W Route K, Columbia, MO 65203 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
302 W. Normal, Kirksville, MO 63501 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1b 29 CFR 1926.150(c)(1)(iv) · Fire protection |
Other-than-serious | $0 | $500 | Oct 25, 2005 | Final |
| Citation 1, item 3 29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements |
Other-than-serious | $2,800 | $2,800 | Oct 25, 2005 | Final |
900 Rollins, Columbia, MO 65203 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
900 Virginia Ave., Columbia, MO 65211 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
900 Virginia Ave., Columbia, MO 65211 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1101 East Rollins, Columbia, MO 65211 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1101 East Rollins, Columbia, MO 65211 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 4a 29 CFR 1926.350(a)(9) · Gas welding and cutting |
Other-than-serious | $1,300 | $650 | Nov 26, 2002 | Final |
| Citation 1, item 4b 29 CFR 1926.350(a)(10) · Gas welding and cutting |
Serious | $0 | $0 | Nov 26, 2002 | Final |
300 E. Podro Simmons Drive, Charleston, MO 63834 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 2 29 CFR 1926.405(a)(2)(iii) · Job-site wiring |
Serious | $1,275 | $1,275 | Mar 5, 2001 | Closed |
| Citation 1, item 3 29 CFR 1926.405(a)(2)(iij) · Job-site wiring |
Other-than-serious | $1,275 | $750 | Mar 5, 2001 | Closed |
Charleston Prison Project, Charleston, MO 63834 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.150(c)(1)(iv)
(iv) One or more fire extinguishers, rated not less than 2A, shall be provided on each floor. In multistory buildings, at least one fire extinguisher shall be located adjacent to stairway.
29 CFR 1926.350(a)(10)
(10) Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.
29 CFR 1926.350(a)(9)
(9) Compressed gas cylinders shall be secured in an upright position at all times except, if necessary, for short periods of time while cylinders are actually being hoisted or carried.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.