Inspection 343311221 OPENED JUL 18, 2018Closed
200 Old Palisade Road, Fort Lee, NJ 07024 · Nonresidential Property Managers · OSHA's record · Phone and website on Google Maps
Incident on Jul 18, 2018: Employee suffers respiratory issues when exposed to heavy co
At 10:30 a.m. on July 18, 2018, Employee #1 and a coworker were repairing the high capacity off line automatic chlorine/bromine pump feeder used to service the community swimming pool. Employee #1 experienced some respiratory irritation after inhaling some chlorine fumes but he continued to work through it. Both employees were exposed to a heavy concentration of fumes when a buildup of them escaped to the surrounding area. Employee #1 had difficulty in breathing due to chemical exposure from the build-up.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.134(c)(1) · Respiratory protection |
Serious | $2,217 | $1,663 | Dec 12, 2018 | Final |
| Citation 1, item 1b 29 CFR 1910.134(e)(1) · Respiratory protection |
Serious | $0 | $0 | Dec 12, 2018 | Final |
| Citation 1, item 1c 29 CFR 1910.134(k)(3) · Respiratory protection |
Serious | $0 | $0 | Dec 12, 2018 | Final |
| Citation 1, item 2 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $2,956 | $2,217 | Dec 12, 2018 | Final |
| Citation 1, item 3a 29 CFR 1910.1200(e)(1) · Hazard communication |
Serious | $2,217 | $1,663 | Dec 12, 2018 | Final |
| Citation 1, item 3b 29 CFR 1910.1200(f)(6) · Hazard communication |
Serious | $0 | $0 | Dec 12, 2018 | Final |
| Citation 1, item 3c 29 CFR 1910.1200(h)(1) · Hazard communication |
Serious | $0 | $0 | Dec 12, 2018 | Final |
| Citation 2, item 1 29 CFR 1910.22(a)(3) · Walking-working surfaces |
Other-than-serious | $0 | $0 | Dec 12, 2018 | Final |