OSHA SearchOSHA records by employer

RM Masonry and Stucco Inc: OSHA inspections and violations

Garland, Texas · Masonry Contractors · NAICS 238140

4inspections
34citation items
$298,346current penalties
Mar 24, 2021last inspection

Since 2018, OSHA inspectors have visited RM Masonry and Stucco Inc in Texas 4 times.

The most recent inspection opened on Mar 24, 2021 as a planned inspection, in Fort Worth and is still open.

In all, OSHA issued 34 citation items: 23 serious and 11 repeat.

The penalties, $298,346 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 22 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. RM Masonry and Stucco Inc averages $74,586 across 4 cited inspections.

RM Masonry and Stucco Inc: OSHA citation items per year, 2018 to 2021
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

12 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch RM Masonry and Stucco Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345214043 OPENED MAR 24, 2021Open

Planned · Partial · Safety · 40 employees at the site · Open

1013 Ne 13th Street, Fort Worth, TX 76102 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(g)(1) · Hazard communication
Serious$4,505$4,505Sep 17, 2021Final
Citation 1, item 2
29 CFR 1926.25(a) · Housekeeping
Serious$4,505$4,505Sep 17, 2021Final
Citation 1, item 3
29 CFR 1926.451(h)(1) · Scaffolds, general requirements
Serious$4,505$4,505Sep 17, 2021Final
Citation 1, item 4
29 CFR 1926.452(c)(4) · Rules for each type of scaffold
Serious$10,513$10,513Sep 17, 2021Final
Citation 1, item 5a
29 CFR 1926.1153(c)(1) · Silica dust in construction
Serious$4,505$4,505Sep 17, 2021Final
Citation 1, item 5b
29 CFR 1926.1153(d)(2)(i) · Silica dust in construction
Serious$0$0Sep 17, 2021Final
Citation 2, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Repeat$12,015$12,015Sep 17, 2021Final
Citation 2, item 2
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Repeat$21,026$21,026Sep 17, 2021Final
Citation 2, item 3a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Repeat$21,026$21,026Sep 17, 2021Final
Citation 2, item 3b
29 CFR 1926.451(e)(9)(iv) · Scaffolds, general requirements
Repeat$0$0Sep 17, 2021Final
Citation 2, item 4
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Repeat$18,023$18,023Sep 17, 2021Final
Citation 2, item 5
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Repeat$21,026$21,026Sep 17, 2021Final
Citation 2, item 6
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Repeat$52,564$52,564Sep 17, 2021Final
Citation 2, item 7
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Repeat$21,026$21,026Sep 17, 2021Final
Citation 2, item 8
29 CFR 1926.454(a) · Scaffold training
Repeat$21,026$21,026Sep 17, 2021Final

Inspection 343801908 OPENED FEB 20, 2019Closed

Planned · Partial · Safety · 2 employees at the site · Closed Mar 9, 2026

705 Ave. B, Garland, TX 75048 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$5,834$5,834Apr 10, 2019Final
Citation 1, item 1b
29 CFR 1926.451(e)(9)(iv) · Scaffolds, general requirements
Serious$0$0Apr 10, 2019Final
Citation 1, item 2
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$5,834$5,834Apr 10, 2019Final
Citation 1, item 4
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$5,834$5,834Apr 10, 2019Final
Citation 1, item 5
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$5,834$5,834Apr 10, 2019Final
Citation 1, item 6
29 CFR 1926.454(a) · Scaffold training
Serious$5,834$5,834Apr 10, 2019Final
Citation 2, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Repeat$11,669$11,669Apr 10, 2019Final

Inspection 343660882 OPENED DEC 12, 2018Closed

Planned · Complete · Safety · 9 employees at the site · Closed May 26, 2026

705 W. Avenue B, Garland, TX 75044 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$2,772$2,772Jan 16, 2019Final
Citation 1, item 2
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$3,880$3,880Jan 16, 2019Final
Citation 1, item 3a
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Serious$3,880$3,880Jan 16, 2019Final
Citation 1, item 3b
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Jan 16, 2019Final
Citation 1, item 3c
29 CFR 1926.451(c)(3) · Scaffolds, general requirements
Serious$0$0Jan 16, 2019Final
Citation 1, item 4
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$3,880$3,880Jan 16, 2019Final

Inspection 343290854 OPENED JUL 11, 2018Closed

Planned · Partial · Safety · 25 employees at the site · Closed Oct 3, 2022

705 W Avenue B, Garland, TX 75040 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$3,253$3,253Sep 12, 2018Final
Citation 1, item 2
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$5,691$5,691Sep 12, 2018Final
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$4,065$4,065Sep 12, 2018Final
Citation 1, item 4a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$5,691$5,691Sep 12, 2018Final
Citation 1, item 4b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Sep 12, 2018Final
Citation 2, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Repeat$8,130$8,130Sep 12, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(g)(1)

(g) Safety data sheets. (1) Chemical manufacturers and importers shall obtain or develop a safety data sheet for each hazardous chemical they produce or import. Employers shall have a safety data sheet in the workplace for each hazardous chemical which they use.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.1153 · Silica dust in construction

29 CFR 1926.1153(c)(1)

(c) Specified exposure control methods. (1) For each employee engaged in a task identified on Table 1, the employer shall fully and properly implement the engineering controls, work practices, and respiratory protection specified for the task on Table 1, unless the employer assesses and limits the exposure of the employee to respirable crystalline silica in accordance with paragraph (d) of this section.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.454 · Scaffold training

Other masonry contractors employers in Texas