OSHA SearchOSHA records by employer

Robert Crawford: OSHA inspections and violations

Hendersonville, North Carolina · Masonry Contractors · NAICS 238140

1inspections
2citation items
$27,800current penalties
Jan 13, 2021last inspection

OSHA has inspected Robert Crawford once in North Carolina.

The inspection began on Jan 13, 2021 after a fatality or catastrophe, in Hendersonville.

That inspection ended with 2 citation items: 2 serious.

Penalties were first proposed at $30,800 and now stand at $27,800, 10% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,079, and Robert Crawford averages $27,800 (1 cited inspection).

1 inspection on this page followed a fatal incident.

Robert Crawford: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Want to know if OSHA cites Robert Crawford again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345103626 OPENED JAN 13, 2021Closed

Fatality or catastrophe · Partial · Safety · 5 employees at the site · Closed Jun 4, 2025

1027 Spartanburg Hwy., Hendersonville, NC 28792 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jan 13, 2021 (fatal): One employee is killed and four coworkers are injured when r

On January 13, 2021, Employee #1 was working in front of a 100 foot by 10 foot concrete retaining wall with Employee #2, Employee #3, Employee #4 and Employee #5. The wall collapsed on top of the employees. Employee #1 was killed and Employee #2, Employee #3 and Employee #4 were hospitalized. Employee #5 was injured and treated and released at the hospital. The employer placed approximately 210 tons of backfill against the newly constructed retaining wall without determining that the structure was capable of supporting the load.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.701(a) · Concrete and Masonry Construction: general requirements
Serious$28,000$27,800Jul 7, 2021Final
Citation 2, item 1
29 CFR 1926.706(b) · Requirements for masonry construction
Serious$2,800$0Jul 7, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.701(a)

(a) Construction loads. No construction loads shall be placed on a concrete structure or portion of a concrete structure unless the employer determines, based on information received from a person who is qualified in structural design, that the structure or portion of the structure is capable of supporting the loads.

29 CFR 1926.706 · Requirements for masonry construction

29 CFR 1926.706(b)

(b) All masonry walls over eight feet in height shall be adequately braced to prevent overturning and to prevent collapse unless the wall is adequately supported so that it will not overturn or collapse. The bracing shall remain in place until permanent supporting elements of the structure are in place.

Other masonry contractors employers in North Carolina