OSHA SearchOSHA records by employer

Robert Crawley: OSHA inspections and violations

Cordova, Tennessee · Finish Carpentry Contractors · NAICS 238350

1inspections
2citation items
$350current penalties
Jul 27, 2022last inspection

Robert Crawley has one OSHA inspection on record in Tennessee.

OSHA opened it on Jul 27, 2022 as a planned inspection, in Cordova.

From that inspection OSHA issued 2 citation items: 2 serious.

OSHA proposed $350 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.502, fall protection systems (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,079. Robert Crawley averages $350 over 1 cited inspection in that time.

Robert Crawley: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Want to know if OSHA cites Robert Crawley again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346108186 OPENED JUL 27, 2022Closed

Planned · Complete · Safety · 2 employees at the site · Closed Sep 22, 2022

2332 North Germantown Parkway, Cordova, TN 38016 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.502(b)(1) · Fall protection systems
Serious$350$350Aug 9, 2022Final
Citation 1, item 1b
29 CFR 1926.502(b)(2) · Fall protection systems
Serious$0$0Aug 9, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.502(b)(1)

(1) Top edge height of top rails, or equivalent guardrail system members, shall be 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level. When conditions warrant, the height of the top edge may exceed the 45-inch height, provided the guardrail system meets all other criteria of this paragraph.

29 CFR 1926.502(b)(2)

(2) Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members shall be installed between the top edge of the guardrail system and the walking/working surface when there is no wall or parapet wall at least 21 inches (53 cm) high.

Other finish carpentry contractors employers in Tennessee

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.