OSHA SearchOSHA records by employer

Robert McHam, Ltd: OSHA inspections and violations

Midland, Texas · Other Automotive Mechanical and Electrical Repair and Maintenance · NAICS 811118

2inspections
13citation items
$9,315current penalties
Mar 13, 2017last inspection

OSHA has inspected Robert McHam, Ltd 2 times in Texas since 2016.

The latest one began on Mar 13, 2017, in Anton.

Those inspections ended with 13 citation items: 13 serious.

Penalties were first proposed at $15,390 and now stand at $9,315, 39% lower after settlements or reviews.

Electrical wiring methods comes up most often in these citations: 9 items under 1910.305.

How that compares: the median penalty per cited inspection for repair and personal services employers since 2015 is $1,200, and Robert McHam, Ltd averages $9,315 (1 cited inspection).

Robert McHam, Ltd: OSHA citation items per year, 2016 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites Robert McHam, Ltd again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342163987 OPENED MAR 13, 2017Closed

Unprogrammed other · Partial · Safety · 20 employees at the site · Closed Oct 4, 2017

Alcfu 604, Anton, TX 79313 · Other Heavy and Civil Engineering Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341269116 OPENED FEB 22, 2016Closed

Complaint · Partial · Safety · 24 employees at the site · Closed Nov 8, 2016

6621 N. Fm 1788, Midland, TX 79707 · Other Automotive Mechanical and Electrical Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.151(c) · First aid and eyewash
Serious$3,240$1,620Jun 28, 2016Final
Citation 1, item 4b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Jun 28, 2016Final
Citation 1, item 5
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$3,240$1,620Jun 28, 2016Final
Citation 1, item 6
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$5,670$2,835Jun 28, 2016Final
Citation 1, item 7a
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$3,240$3,240Jun 28, 2016Final
Citation 1, item 7b
29 CFR 1910.305(b)(3)(i) · Electrical wiring methods
Serious$0$0Jun 28, 2016Final
Citation 1, item 7c
29 CFR 1910.305(c)(2) · Electrical wiring methods
Serious$0$0Jun 28, 2016Final
Citation 1, item 7d
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$0$0Jun 28, 2016Final
Citation 1, item 7e
29 CFR 1910.305(g)(1)(iv)(b) · Electrical wiring methods
Serious$0$0Jun 28, 2016Final
Citation 1, item 7f
29 CFR 1910.305(g)(1)(iv)(c) · Electrical wiring methods
Serious$0$0Jun 28, 2016Final
Citation 1, item 7g
29 CFR 1910.305(g)(1)(iv)(d) · Electrical wiring methods
Serious$0$0Jun 28, 2016Final
Citation 1, item 7h
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Serious$0$0Jun 28, 2016Final
Citation 1, item 7i
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Jun 28, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.151(c)

(c) Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.219(e)(1)(i)

(e) Belt, rope, and chain drives—(1) Horizontal belts and ropes. (i) Where both runs of horizontal belts are seven (7) feet or less from the floor level, the guard shall extend to at least fifteen (15) inches above the belt or to a standard height except that where both runs of a horizontal belt are 42 inches or less from the floor, the belt shall be fully enclosed in accordance with paragraphs (m) and (o) of this section.

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.253(b)(4)(iii)

(iii) Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other other automotive mechanical and electrical repair and maintenance employers in Texas