Roberto Adame: OSHA inspections and violations

Spring, Texas · Masonry Contractors · NAICS 238140

1inspections
3citation items
$5,969current penalties
May 3, 2021last inspection

Roberto Adame has one OSHA inspection on record in Texas.

OSHA opened it on May 3, 2021 as a planned inspection, in Spring.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $9,948 in penalties. After settlements and reviews the total is $5,969, down 40%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,079. Roberto Adame averages $5,969 over 1 cited inspection in that time.

Roberto Adame: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Want to know if OSHA cites Roberto Adame again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345285860 OPENED MAY 3, 2021Closed

Planned · Partial · Safety · 5 employees at the site · Closed Jul 17, 2023

26118 I-45, Spring, TX 77386 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,926$1,756May 17, 2021Final
Citation 1, item 2
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$4,096$2,458May 17, 2021Final
Citation 1, item 3
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$2,926$1,756May 17, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(c)(2)

(2) Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured.

Other masonry contractors employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.