OSHA SearchOSHA records by employer

Roberto Fernandez: OSHA inspections and violations

Garland, Texas · Roofing Contractors · NAICS 238160

5inspections
9citation items
$17,271current penalties
Apr 12, 2021last inspection

Roberto Fernandez has 5 OSHA inspections on record in Texas, the first in 2007.

OSHA's last visit started on Apr 12, 2021 as a planned inspection, in Lubbock.

Across those inspections OSHA issued 9 citation items: 6 serious and 3 repeat.

OSHA proposed $21,831 in penalties. After settlements and reviews the total is $17,271, down 21%.

Most often, OSHA cited 1926.501, fall protection in construction (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Roberto Fernandez averages $4,636 over 2 cited inspections in that time.

Roberto Fernandez: OSHA citation items per year, 2007 to 2021
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

48 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Roberto Fernandez and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345245690 OPENED APR 12, 2021Closed

Planned · Partial · Safety · 5 employees at the site · Closed Dec 31, 2025

6548 43rd (raider Ranch Blg 400 236&238), Lubbock, TX 79407 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$1,492$1,492Jun 7, 2021Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,492$1,492Jun 7, 2021Final
Citation 1, item 3
29 CFR 1926.602(d) · Earthmovers and forklifts in construction
Serious$1,755$1,755Jun 7, 2021Final
Citation 1, item 4
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,492$1,492Jun 7, 2021Final

Inspection 340826387 OPENED AUG 5, 2015Closed

Referral · Partial · Safety · 9 employees at the site · Closed May 16, 2016

1410 S. Goliad Street, Rockwall, TX 75087 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$2,000$800Oct 5, 2015Final
Citation 2, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$5,600$2,240Oct 5, 2015Final

Inspection 336226204 OPENED SEP 6, 2012Closed

Planned · Partial · Safety · 150 employees at the site · Closed Sep 7, 2012

26 Skyline Drive, Trophy Club, TX 76262 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 315184275 OPENED FEB 15, 2011Closed

Planned · Partial · Safety · 5 employees at the site · Closed Jun 4, 2013

116 Port St. Claire, Aransas Pass, TX 78336 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,400$2,400Mar 16, 2011Closed

Inspection 309543486 OPENED APR 11, 2007Closed

Unprogrammed other · Partial · Safety · 25 employees at the site · Closed Jul 11, 2013

1044 E Interstate 30, Garland, TX 75043 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$4,000$4,000May 11, 2007Closed
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Repeat$1,600$1,600May 11, 2007Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.602 · Earthmovers and forklifts in construction

Other roofing contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.