OSHA SearchOSHA records by employer

Roberto Flores: OSHA inspections and violations

Waco, Texas · Masonry Contractors · NAICS 238140

2inspections
7citation items
$9,690current penalties
Aug 3, 2016last inspection

Since 2006, OSHA inspectors have visited Roberto Flores in Texas 2 times.

The most recent inspection opened on Aug 3, 2016 as a planned inspection, in Farmers Branch.

In all, OSHA issued 7 citation items: 7 serious.

The proposed penalties came to $16,476; today they stand at $9,690, 41% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 5 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,079 penalty. Roberto Flores averages $4,440 across 1 cited inspection.

Roberto Flores: OSHA citation items per year, 2006 to 2016
Citation items per year, by inspection date.

Want to know if OSHA cites Roberto Flores again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341667152 OPENED AUG 3, 2016Closed

Planned · Partial · Safety · 10 employees at the site · Closed Dec 11, 2019

11411 Luna Rd., Farmers Branch, TX 75234 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$3,742$1,480Aug 12, 2016Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,742$1,480Aug 12, 2016Final
Citation 1, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$3,742$1,480Aug 12, 2016Final

Inspection 308650852 OPENED MAR 22, 2006Closed

Unprogrammed related · Complete · Safety · 20 employees at the site · Closed Sep 17, 2010

1410 James Ave., Waco, TX 76706 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements
Serious$750$750Jun 7, 2006Closed
Citation 1, item 2
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$1,500$1,500Jun 7, 2006Closed
Citation 1, item 3
29 CFR 1926.452(c)(4) · Rules for each type of scaffold
Serious$1,500$1,500Jun 7, 2006Closed
Citation 1, item 4
29 CFR 1926.452(c)(5)(iii) · Rules for each type of scaffold
Serious$1,500$1,500Jun 7, 2006Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(b)(5)(ii)

(ii) Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.452 · Rules for each type of scaffold

Other masonry contractors employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.