OSHA SearchOSHA records by employer

Robin Builders, Inc.: OSHA inspections and violations

Lake Wales, Florida · All Other Miscellaneous Nonmetallic Mineral Product Manufacturing · NAICS 327999

3inspections
20citation items
$11,435current penalties
Jul 22, 2025last inspection

Since 1983, OSHA inspectors have visited Robin Builders, Inc. in Florida 3 times.

The most recent inspection opened on Jul 22, 2025 after a complaint, in Lake Wales.

In all, OSHA issued 20 citation items: 16 serious and 4 other-than-serious.

The proposed penalties came to $18,472; today they stand at $11,435, 38% less.

The rule cited most here is 1910.217 (mechanical power presses), 6 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Robin Builders, Inc. averages $10,555 across 1 cited inspection.

Robin Builders, Inc.: OSHA citation items per year, 1983 to 2025
Citation items per year, by inspection date.

Want to know if OSHA cites Robin Builders, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348387267 OPENED JUL 22, 2025Closed

Complaint · Partial · Safety · 6 employees at the site · Closed Mar 16, 2026

14915 Us-27, Lake Wales, FL 33859 · All Other Miscellaneous Nonmetallic Mineral Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(1) · Walking-working surfaces
Serious$3,972$2,383Dec 29, 2025Final
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$3,972$2,383Dec 29, 2025Final
Citation 1, item 3
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$2,838$1,703Dec 29, 2025Final
Citation 1, item 4
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$3,972$2,383Dec 29, 2025Final
Citation 1, item 5
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$2,838$1,703Dec 29, 2025Final

Inspection 14027809 OPENED JUL 12, 1983Closed

Follow-up · Partial · Safety · 25 employees at the site · Closed Jul 22, 1983

4419 Us 27 South, Lake Wales, FL 33853 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 14027668 OPENED JUN 1, 1983Closed

Planned · Complete · Safety · 25 employees at the site · Closed Aug 17, 1983

4419 Us 27 South, Lake Wales, FL 33853 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$120$120Jun 10, 1983Closed
Citation 1, item 2a
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$120$120Jun 10, 1983Closed
Citation 1, item 2b
29 CFR 1910.213(h)(4) · Woodworking machinery
Serious$0$0Jun 10, 1983Closed
Citation 1, item 3a
29 CFR 1910.217(c)(1)(i) · Mechanical power presses
Serious$200$200Jun 10, 1983Closed
Citation 1, item 3b
29 CFR 1910.217(b)(3)(i) · Mechanical power presses
Serious$0$0Jun 10, 1983Closed
Citation 1, item 3c
29 CFR 1910.217(b)(4)(i) · Mechanical power presses
Serious$0$0Jun 10, 1983Closed
Citation 1, item 3d
29 CFR 1910.217(b)(8)(iii) · Mechanical power presses
Serious$0$0Jun 10, 1983Closed
Citation 1, item 3e
29 CFR 1910.217(d)(5) · Mechanical power presses
Serious$0$0Jun 10, 1983Closed
Citation 1, item 4
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$160$160Jun 10, 1983Closed
Citation 1, item 5
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$120$120Jun 10, 1983Closed
Citation 1, item 6
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$160$160Jun 10, 1983Closed
Citation 2, item 1
29 CFR 1910.28(d)(13) · Safety requirements for scaffolding
Other-than-serious$0$0Jun 10, 1983Closed
Citation 2, item 2
29 CFR 1910.217(e)(1)(i) · Mechanical power presses
Other-than-serious$0$0Jun 10, 1983Closed
Citation 2, item 3
29 CFR 1910.219(b)(1) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Jun 10, 1983Closed
Citation 2, item 4
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Jun 10, 1983Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(3)(ii)

(ii) The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(h)(1)

(h) Radial saws. (1) The upper hood shall completely enclose the upper portion of the blade down to a point that will include the end of the saw arbor. The upper hood shall be constructed in such a manner and of such material that it will protect the operator from flying splinters, broken saw teeth, etc., and will deflect sawdust away from the operator. The sides of the lower exposed portion of the blade shall be guarded to the full diameter of the blade by a device that will automatically adjust itself to the thickness of the stock and remain in contact with stock being cut to give maximum protection possible for the operation being performed.

29 CFR 1910.213(h)(4)

(4) Installation shall be in such a manner that the front end of the unit will be slightly higher than the rear, so as to cause the cutting head to return gently to the starting position when released by the operator.

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · Walking-working surfaces

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.28 · Safety requirements for scaffolding

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

Other all other miscellaneous nonmetallic mineral product manufacturing employers in Florida

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.