Robovent Solutions Group: OSHA inspections and violations
Sterling Heights, Michigan · Industrial Machinery and Equipment Merchant Wholesalers · NAICS 423830
1inspections
1citation items
$1,750current penalties
Aug 30, 2021last inspection
OSHA inspectors have visited Robovent Solutions Group in Michigan one time.
It opened on Aug 30, 2021 as a planned inspection, in Sterling Heights.
In all, OSHA issued 1 citation item: 1 serious.
The proposed penalties came to $3,500; today they stand at $1,750, 50% less.
Among wholesale employers, the typical cited inspection since 2015 ends with a $3,425 penalty. Robovent Solutions Group averages $1,750 across 1 cited inspection.
Robovent Solutions Group also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Michigan · latest 90 days of OSHA records
653employers cited
Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.
Incident on May 26, 2021: Employee receives electrical burns from energized terminal l
At 7:45 p.m. on May 26, 2021, an employee was reaching into a powered electrical cabinet on an industrial ventilation machine to tighten a component. During the task, the employee's left forearm touched a terminal lug energized with 480 volts. The employee sustained electrical burns to the left forearm and right palm. The employee was treated without hospitalization.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2020, the Sterling Heights site logged 2 recordable injuries or illnesses among about 111 workers: 1.9 per 100 full-time workers, against a median of 1.8 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Robovent Solutions Group
Sterling Heights · 2020
111
2
0
1.9
1.8
Included with any plan: 1 more yearly log from these sites, back to 2019, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(1) Deenergized parts. Live parts to which an employee may be exposed shall be deenergized before the employee works on or near them, unless the employer can demonstrate that deenergizing introduces additional or increased hazards or is infeasible due to equipment design or operational limitations. Live parts that operate at less than 50 volts to ground need not be deenergized if there will be no increased exposure to electrical burns or to explosion due to electric arcs.