OSHA SearchOSHA records by employer

Rob's General Contracting Inc: OSHA inspections and violations

Reading, Pennsylvania · Roofing Contractors · NAICS 238160

5inspections
10citation items
$10,247current penalties
Jul 3, 2019last inspection

Since 2007, OSHA inspectors have visited Rob's General Contracting Inc in Pennsylvania 5 times.

The most recent inspection opened on Jul 3, 2019 after a complaint, in Elysburg.

In all, OSHA issued 10 citation items: 8 serious, 1 repeat and 1 other-than-serious.

The proposed penalties came to $13,627; today they stand at $10,247, 25% less.

The rule cited most here is 1926.501 (fall protection in construction), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Rob's General Contracting Inc averages $2,042 across 3 cited inspections.

Rob's General Contracting Inc: OSHA citation items per year, 2007 to 2019
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

285employers cited

30 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Rob's General Contracting Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344132907 OPENED JUL 3, 2019Closed

Complaint · Partial · Safety · 4 employees at the site · Closed Apr 3, 2023

St. Mark's Luthern Church 225 N. Market St., Elysburg, PA 17824 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$2,415$2,415Aug 6, 2019Final
Citation 2, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Repeat$212$212Aug 6, 2019Final

Inspection 341477743 OPENED MAY 12, 2016Closed

Complaint · Partial · Safety · 3 employees at the site · Closed Jan 19, 2017

827 Bottle Drive, Paxinos, PA 17860 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,000$1,500Jun 15, 2016Final

Inspection 340683317 OPENED JUN 5, 2015Closed

Referral · Complete · Safety · 8 employees at the site · Closed Jan 11, 2016

500 North Main St., Plains Township, PA 18705 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$2,800$2,000Sep 8, 2015Final

Inspection 339773244 OPENED MAY 19, 2014Closed

Complaint · Complete · Safety · 4 employees at the site · Closed Jul 9, 2014

1700 West Fourth Street, Williamsport, PA 17701 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.150(c)(1)(vi) · Fire protection
Serious$1,200$780May 30, 2014Final
Citation 1, item 3
29 CFR 1926.502(d)(15) · Fall protection systems
Other-than-serious$2,000$1,300May 30, 2014Final
Citation 1, item 4
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Serious$1,200$780May 30, 2014Final

Inspection 310838404 OPENED JUN 12, 2007Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Jun 28, 2007

Pa State Police, 600 Kenhorst Boulevard, Reading, PA 19611 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(i) · Scaffolds, general requirements
Serious$600$420Jun 21, 2007Closed
Citation 1, item 2
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$600$420Jun 21, 2007Closed
Citation 1, item 3
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$600$420Jun 21, 2007Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(vi)

(vi) A fire extinguisher, rated not less than 10B, shall be provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas are being used on the jobsite. This requirement does not apply to the integral fuel tanks of motor vehicles.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems