OSHA SearchOSHA records by employer

Rock Solid Masonry, Inc.: OSHA inspections and violations

Fargo, North Dakota · Masonry Contractors · NAICS 238140

2inspections
4citation items
$7,447current penalties
Mar 7, 2023last inspection

OSHA has inspected Rock Solid Masonry, Inc. 2 times in North Dakota since 2018.

The latest one began on Mar 7, 2023 as a planned inspection, in Fargo.

Those inspections ended with 4 citation items: 4 serious.

Penalties were first proposed at $14,180 and now stand at $7,447, 47% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,079, and Rock Solid Masonry, Inc. averages $3,724 (2 cited inspections).

Rock Solid Masonry, Inc.: OSHA citation items per year, 2018 to 2023
Citation items per year, by inspection date.

Want to know if OSHA cites Rock Solid Masonry, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346562895 OPENED MAR 7, 2023Closed

Planned · Partial · Health · 18 employees at the site · Closed Jul 13, 2023

5801 51st Avenue South, Fargo, ND 58104 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1153(c)(1) · Silica dust in construction
Serious$3,572$2,143May 19, 2023Final

Inspection 343572798 OPENED OCT 30, 2018Closed

Planned · Partial · Safety · 19 employees at the site · Closed Jun 17, 2019

Near The Intersection Of 26th Avenue South & 41st Street South, Fargo, ND 58104 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Serious$5,304$2,652Apr 2, 2019Final
Citation 1, item 1b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Apr 2, 2019Final
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$5,304$2,652Apr 2, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1153 · Silica dust in construction

29 CFR 1926.1153(c)(1)

(c) Specified exposure control methods. (1) For each employee engaged in a task identified on Table 1, the employer shall fully and properly implement the engineering controls, work practices, and respiratory protection specified for the task on Table 1, unless the employer assesses and limits the exposure of the employee to respirable crystalline silica in accordance with paragraph (d) of this section.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(1)

(c) Criteria for supported scaffolds. (1) Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means, as follows:

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.