Inspection 345598221 OPENED OCT 21, 2021Closed
Lot #403 The Park Subdivision, Layton, UT 84040 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2010, OSHA inspectors have visited Rock Solid Roofing in Utah 15 times.
The most recent inspection opened on Oct 21, 2021 on a referral, in Layton.
In all, OSHA issued 16 citation items: 15 serious and 1 repeat.
The proposed penalties came to $36,025; today they stand at $24,622, 32% less.
The rule cited most here is 1926.501 (fall protection in construction), 8 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,078 penalty. Rock Solid Roofing averages $1,125 across 2 cited inspections.
Want to know if OSHA cites Rock Solid Roofing again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this companyLot #403 The Park Subdivision, Layton, UT 84040 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1689 W 3040 N, Pleasant Grove, UT 84062 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4502 W. Birkdale Dr. Lot #45, Herriman, UT 84096 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(10) · Fall protection in construction |
Serious | $1,500 | $1,500 | Jun 22, 2020 | Final |
3186 W 2400 N, Lehi, UT 84043 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
773 West 750 South, Layton, UT 84041 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.501(b)(11) · Fall protection in construction |
Serious | $1,500 | $750 | May 4, 2016 | Final |
| Citation 1, item 1b 29 CFR 1926.503(c)(3) · Fall protection training in construction |
Serious | $0 | $0 | May 4, 2016 | Final |
1203 S Meadow Walk Dr, Heber City, UT 84032 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
5405 W Old Pine Court, Riverton, UT 84065 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(11) · Fall protection in construction |
Repeat | $10,000 | $4,688 | Aug 26, 2013 | Closed |
607 W 2660 N, Lehi, UT 84043 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.502(d)(17) · Fall protection systems |
Serious | $625 | $625 | Jun 24, 2013 | Closed |
Lot 221 Garden Park Development, South Jordan, UT 84020 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(11) · Fall protection in construction |
Serious | $1,500 | $1,500 | May 7, 2013 | Closed |
Shinnerock Dr Lot 205, South Jordon, UT 84064 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(11) · Fall protection in construction |
Serious | $2,000 | $2,000 | Apr 29, 2013 | Closed |
244 Spanish Highlands: 2048 E 280 S, Spanish Fork, UT 84660 · Residential Remodelers · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(11) · Fall protection in construction |
Serious | $2,000 | $2,000 | Dec 9, 2011 | Closed |
| Citation 1, item 2 29 CFR 1926.502(d)(16)(iii) · Fall protection systems |
Serious | $2,000 | $2,000 | Dec 9, 2011 | Closed |
| Citation 1, item 3 29 CFR 1926.1053(b)(1) · Ladders in construction |
Serious | $2,000 | $2,000 | Dec 9, 2011 | Closed |
13244 S Lone Peak Dr, Draper, UT 84020 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.403(b)(1) · Electrical equipment on job sites |
Serious | $2,000 | $2,000 | Oct 27, 2011 | Closed |
4044 Rose Springs Rd, Erda, UT 84074 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(13) · Fall protection in construction |
Serious | $2,000 | $2,000 | Oct 25, 2011 | Closed |
6208 S 3200 W, Taylorsville, UT 84118 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites |
Serious | $1,400 | $560 | Oct 25, 2010 | Closed |
| Citation 1, item 2 29 CFR 1926.501(b)(11) · Fall protection in construction |
Serious | $2,500 | $1,000 | Oct 25, 2010 | Closed |
| Citation 1, item 3 29 CFR 1926.503(c)(3) · Fall protection training in construction |
Serious | $2,500 | $1,000 | Oct 25, 2010 | Closed |
| Citation 1, item 4 29 CFR 1926.1053(b)(1) · Ladders in construction |
Serious | $2,500 | $1,000 | Oct 25, 2010 | Closed |
Highbury Subdivision Lots 120-125, West Valley City, UT 84120 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.1053(b)(1)
(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.
29 CFR 1926.403(b)(1)
(b) Examination, installation, and use of equipment—(1) Examination. The employer shall ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined on the basis of the following considerations:
29 CFR 1926.404(b)(1)(i)
(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.