OSHA SearchOSHA records by employer

Rockwerx, Inc.: OSHA inspections and violations

Portland, Maine · All Other Miscellaneous Fabricated Metal Product Manufacturing · NAICS 332999

1inspections
6citation items
$9,310current penalties
Jan 5, 2015last inspection

Rockwerx, Inc. has one OSHA inspection on record in Maine.

OSHA opened it on Jan 5, 2015 after a complaint, in Portland.

From that inspection OSHA issued 6 citation items: 5 serious and 1 other-than-serious.

OSHA proposed $13,300 in penalties. After settlements and reviews the total is $9,310, down 30%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Rockwerx, Inc. averages $9,310 over 1 cited inspection in that time.

Rockwerx, Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Maine · latest 90 days of OSHA records

31employers cited

Get notified the morning OSHA posts each new citation in Maine: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maine

Checking a subcontractor, a client or your own company? Watch Rockwerx, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340162247 OPENED JAN 5, 2015Closed

Complaint · Complete · Safety · 5 employees at the site · Closed Mar 28, 2016

65 Warren Avenue, Portland, ME 04103 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$3,500$2,450Feb 4, 2015Final
Citation 1, item 2a
29 CFR 1926.451(g)(3) · Scaffolds, general requirements
Serious$4,900$3,430Feb 4, 2015Final
Citation 1, item 2b
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$0$0Feb 4, 2015Final
Citation 1, item 3a
29 CFR 1926.452(w)(7) · Rules for each type of scaffold
Serious$4,900$3,430Feb 4, 2015Final
Citation 1, item 3b
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$0$0Feb 4, 2015Final
Citation 2, item 1
29 CFR 1926.59 · Hazard communication
Other-than-serious$0$0Feb 4, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(6)

(6) Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section.

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.59 · Hazard communication

Other all other miscellaneous fabricated metal product manufacturing employers in Maine

Alert subscribers get notified of each newly cited employer in Maine the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.