OSHA SearchOSHA records by employer

Rodriguez Masonry: OSHA inspections and violations

Cedar Hill, Texas · Masonry Contractors · NAICS 238140

6inspections
15citation items
$14,254current penalties
Nov 15, 2021last inspection

Rodriguez Masonry has 6 OSHA inspections on record in Texas, the first in 2005.

OSHA's last visit started on Nov 15, 2021 as a planned inspection, in Frisco.

Across those inspections OSHA issued 15 citation items: 15 serious.

OSHA proposed $18,705 in penalties. After settlements and reviews the total is $14,254, down 24%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (12 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Rodriguez Masonry averages $5,702 over 2 cited inspections in that time.

Rodriguez Masonry: OSHA citation items per year, 2005 to 2021
Citation items per year, by inspection date.

Want to know if OSHA cites Rodriguez Masonry again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345641534 OPENED NOV 15, 2021Closed

Planned · Partial · Safety · 3 employees at the site · Closed Dec 15, 2021

1165 Helmsley Drive, Frisco, TX 75036 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345414767 OPENED JUL 13, 2021Open

Planned · Partial · Safety · 4 employees at the site · Open

1128 W Dallas Street, Conroe, TX 77301 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,926$2,926Jul 29, 2021Final
Citation 1, item 2
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$2,926$2,926Jul 29, 2021Final

Inspection 344943956 OPENED SEP 24, 2020Closed

Planned · Partial · Safety · 4 employees at the site · Closed Apr 26, 2022

12996 Averi, Farmers Branch, TX 75234 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$2,313$1,388Oct 2, 2020Final
Citation 1, item 2a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$4,048$2,429Oct 2, 2020Final
Citation 1, item 2b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Oct 2, 2020Final
Citation 1, item 2c
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Oct 2, 2020Final
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,892$1,735Oct 2, 2020Final

Inspection 314869025 OPENED OCT 6, 2010Closed

Planned · Partial · Safety · 4 employees at the site · Closed Nov 1, 2013

214 N. 14th Street, Kingsville, TX 78363 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$450$450Oct 22, 2010Closed
Citation 1, item 2
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$450$450Oct 22, 2010Closed
Citation 1, item 3
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$750$750Oct 22, 2010Closed

Inspection 314670126 OPENED AUG 4, 2010Closed

Planned · Partial · Safety · 22 employees at the site · Closed Mar 14, 2013

1600 E. Tyler Ave, Harlingen, TX 78550 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.25(a) · Housekeeping
Serious$225$225Sep 30, 2010Closed
Citation 1, item 2
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$225$225Sep 30, 2010Closed

Inspection 307488783 OPENED FEB 9, 2005Closed

Planned · Partial · Safety · 7 employees at the site · Closed Aug 4, 2010

804 Beltline Road, Cedar Hill, TX 75104 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,500$750Apr 27, 2005Closed
Citation 1, item 1b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Apr 27, 2005Closed
Citation 1, item 1c
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Apr 27, 2005Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.25(a)

(a) During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, shall be kept cleared from work areas, passageways, and stairs, in and around buildings or other structures.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.452 · Rules for each type of scaffold

Other masonry contractors employers in Texas