OSHA SearchOSHA records by employer

Rodriguez Underground Construction Company: OSHA inspections and violations

Kansas City, Missouri · Site Preparation Contractors · NAICS 238910

2inspections
3citation items
$4,284current penalties
Jul 13, 2016last inspection

Rodriguez Underground Construction Company has 2 OSHA inspections on record in Missouri, the first in 2016.

OSHA's last visit started on Jul 13, 2016 to follow up on an earlier case, in Kansas City.

Across those inspections OSHA issued 3 citation items: 3 serious.

OSHA proposed $6,120 in penalties. After settlements and reviews the total is $4,284, down 30%.

Most often, OSHA cited 1926.651, excavations (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Rodriguez Underground Construction Company averages $4,284 over 1 cited inspection in that time.

Rodriguez Underground Construction Company: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Missouri · latest 90 days of OSHA records

118employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Missouri: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Missouri

Checking a subcontractor, a client or your own company? Watch Rodriguez Underground Construction Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341615748 OPENED JUL 13, 2016Closed

Follow-up · Partial · Safety · 6 employees at the site · Closed Jul 13, 2016

10130 Nw Prairie View Rd, Kansas City, MO 64153 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341281525 OPENED FEB 25, 2016Closed

Planned · Complete · Safety · 6 employees at the site · Closed Dec 13, 2019

10130 Nw Prairie View Road, Kansas City, MO 64153 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$2,160$1,512Mar 4, 2016Final
Citation 1, item 2
29 CFR 1926.651(k)(1) · Excavations
Serious$1,440$1,008Mar 4, 2016Final
Citation 1, item 3
29 CFR 1926.652(a)(1) · Trench protection
Serious$2,520$1,764Mar 4, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(a)(1)

(a) Protection of employees in excavations. (1) Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when:

Other site preparation contractors employers in Missouri

Alert subscribers get notified of each newly cited employer in Missouri the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.