OSHA SearchOSHA records by employer

Rogelio Ramos Masonry: OSHA inspections and violations

Lubbock, Texas · Masonry Contractors · NAICS 238140

3inspections
14citation items
$23,316current penalties
Mar 5, 2020last inspection

OSHA has inspected Rogelio Ramos Masonry 3 times in Texas since 2016.

The latest one began on Mar 5, 2020 as a planned inspection, in Lubbock.

Those inspections ended with 14 citation items: 11 serious and 3 repeat.

Penalties were first proposed at $31,389 and now stand at $23,316, 26% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 6 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Rogelio Ramos Masonry averages $7,772 (3 cited inspections).

Rogelio Ramos Masonry: OSHA citation items per year, 2016 to 2020
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Rogelio Ramos Masonry and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344676580 OPENED MAR 5, 2020Closed

Planned · Partial · Health · 3 employees at the site · Closed Nov 10, 2021

4930 118th St., Lubbock, TX 79424 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,735$1,735May 1, 2020Final
Citation 1, item 2a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,735$1,735May 1, 2020Final
Citation 1, item 2b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0May 1, 2020Final
Citation 2, item 1
29 CFR 1926.59 · Hazard communication
Repeat$3,470$3,470May 1, 2020Final
Citation 2, item 2
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Repeat$3,470$3,470May 1, 2020Final
Citation 2, item 3
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Repeat$3,470$3,470May 1, 2020Final

Inspection 344286745 OPENED SEP 5, 2019Closed

Planned · Partial · Health · 6 employees at the site · Closed Jan 6, 2020

82nd St., Lubbock, TX 79424 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,273$1,364Nov 19, 2019Final
Citation 1, item 2
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$2,273$1,364Nov 19, 2019Final
Citation 1, item 3
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$2,273$1,364Nov 19, 2019Final

Inspection 341822971 OPENED OCT 6, 2016Closed

Planned · Partial · Health · 10 employees at the site · Closed Dec 12, 2018

4911 119th Street, Lubbock, TX 79424 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.59 · Hazard communication
Serious$2,672$1,336Nov 7, 2016Final
Citation 1, item 2
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$1,604$802Nov 7, 2016Final
Citation 1, item 3
29 CFR 1926.403(b)(1) · Electrical equipment on job sites
Serious$2,138$1,069Nov 7, 2016Final
Citation 1, item 4
29 CFR 1926.405(g)(2)(iii) · Job-site wiring
Serious$2,138$1,069Nov 7, 2016Final
Citation 1, item 5
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$2,138$1,069Nov 7, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(1)

(b) Examination, installation, and use of equipment—(1) Examination. The employer shall ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined on the basis of the following considerations:

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(2)(iii)

(iii) Splices. Flexible cords shall be used only in continuous lengths without splice or tap. Hard service flexible cords No. 12 or larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.59 · Hazard communication