Inspection 340208545 OPENED SEP 14, 2016Closed
31790 Groesbeck Hwy, Fraser, MI 48026 · Special Die and Tool, Die Set, Jig, and Fixture Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Rolled Shapes & Engineering Inc has 3 OSHA inspections on record in Michigan, the first in 2016.
OSHA's last visit started on Sep 14, 2016 to follow up on an earlier case, in Fraser.
Across those inspections OSHA issued 41 citation items: 25 serious, 2 repeat and 14 other-than-serious.
OSHA proposed $18,100 in penalties and the amount has not been reduced.
Most often, OSHA cited 1910.305, electrical wiring methods (4 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Rolled Shapes & Engineering Inc averages $9,050 over 2 cited inspections in that time.
Michigan · latest 90 days of OSHA records
647employers cited
3 of them in the same industry
Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Michigan
Checking a subcontractor, a client or your own company? Watch Rolled Shapes & Engineering Inc and get notified the morning OSHA posts a new citation for it.
Watch this company31790 Groesbeck Hwy, Fraser, MI 48026 · Special Die and Tool, Die Set, Jig, and Fixture Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
31790 Groesbeck Hwy, Fraser, MI 48026 · Special Die and Tool, Die Set, Jig, and Fixture Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.1200(e)(1) · Hazard communication |
Serious | $200 | $200 | Apr 15, 2016 | Final |
| Citation 1, item 2 29 CFR 325.52007 |
Serious | $250 | $250 | Apr 15, 2016 | Final |
| Citation 1, item 3 29 CFR 325.60006(1) |
Serious | $200 | $200 | Apr 15, 2016 | Final |
| Citation 2, item 1a 29 CFR 4201(3)(A)(V) |
Other-than-serious | $50 | $50 | Apr 15, 2016 | Final |
| Citation 2, item 1b 29 CFR 4201(4)(A) |
Other-than-serious | $0 | $0 | Apr 15, 2016 | Final |
| Citation 2, item 1c 29 CFR 4201(4)(B)(IV) |
Other-than-serious | $0 | $0 | Apr 15, 2016 | Final |
| Citation 2, item 2 29 CFR 1910.134(k)(6) · Respiratory protection |
Other-than-serious | $0 | $0 | Apr 15, 2016 | Final |
31790 Groesbeck Hwy, Fraser, MI 48026 · Special Die and Tool, Die Set, Jig, and Fixture Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 408.10121(1) |
Serious | $450 | $450 | May 12, 2016 | Final |
| Citation 1, item 1b 29 CFR 408.10187(1) |
Serious | $0 | $0 | May 12, 2016 | Final |
| Citation 1, item 2 29 CFR 408.10711 |
Serious | $750 | $750 | May 12, 2016 | Final |
| Citation 1, item 3 29 CFR 408.10716 |
Serious | $750 | $750 | May 12, 2016 | Final |
| Citation 1, item 4 29 CFR 408.10727(1) |
Serious | $750 | $750 | May 12, 2016 | Final |
| Citation 1, item 5 29 CFR 408.10731(1) |
Serious | $750 | $750 | May 12, 2016 | Final |
| Citation 1, item 6a 29 CFR 408.11222(3) |
Serious | $600 | $600 | May 12, 2016 | Final |
| Citation 1, item 6b 29 CFR 408.11223(1) |
Serious | $0 | $0 | May 12, 2016 | Final |
| Citation 1, item 7 29 CFR 408.12154(1) |
Serious | $600 | $600 | May 12, 2016 | Final |
| Citation 1, item 8a 29 CFR 408.12411(2) |
Serious | $1,000 | $1,000 | May 12, 2016 | Final |
| Citation 1, item 8b 29 CFR 408.12412(1) |
Serious | $0 | $0 | May 12, 2016 | Final |
| Citation 1, item 9 29 CFR 408.12477(1) |
Serious | $2,000 | $2,000 | May 12, 2016 | Final |
| Citation 1, item 10 29 CFR 408.12637 |
Serious | $750 | $750 | May 12, 2016 | Final |
| Citation 1, item 11a 29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements |
Serious | $750 | $750 | May 12, 2016 | Final |
| Citation 1, item 11b 29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements |
Serious | $0 | $0 | May 12, 2016 | Final |
| Citation 1, item 11c 29 CFR 1910.305(b)(2)(i) · Electrical wiring methods |
Serious | $0 | $0 | May 12, 2016 | Final |
| Citation 1, item 12 29 CFR 408.14945(1) |
Serious | $750 | $750 | May 12, 2016 | Final |
| Citation 1, item 13a 29 CFR 408.14961 |
Serious | $750 | $750 | May 12, 2016 | Final |
| Citation 1, item 13b 29 CFR 408.14965(1) |
Serious | $0 | $0 | May 12, 2016 | Final |
| Citation 1, item 14a 29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout |
Serious | $750 | $750 | May 12, 2016 | Final |
| Citation 1, item 14b 29 CFR 1910.147(c)(7)(i)(b) · Lockout/tagout |
Serious | $0 | $0 | May 12, 2016 | Final |
| Citation 1, item 14c 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Serious | $0 | $0 | May 12, 2016 | Final |
| Citation 2, item 1 29 CFR 408.12461(1) |
Repeat | $4,000 | $4,000 | May 12, 2016 | Final |
| Citation 2, item 2 29 CFR 408.12641(1) |
Repeat | $2,000 | $2,000 | May 12, 2016 | Final |
| Citation 3, item 1 29 CFR 408.10015(1) |
Other-than-serious | $0 | $0 | May 12, 2016 | Final |
| Citation 3, item 2 29 CFR 408.10835(3) |
Other-than-serious | $0 | $0 | May 12, 2016 | Final |
| Citation 3, item 3 29 CFR 408.13308(3) |
Other-than-serious | $0 | $0 | May 12, 2016 | Final |
| Citation 3, item 4a 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | May 12, 2016 | Final |
| Citation 3, item 4b 29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | May 12, 2016 | Final |
| Citation 3, item 4c 29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | May 12, 2016 | Final |
| Citation 3, item 4d 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | May 12, 2016 | Final |
| Citation 3, item 5a 29 CFR 408.14007(4) |
Other-than-serious | $0 | $0 | May 12, 2016 | Final |
| Citation 3, item 5b 29 CFR 408.14007(7) |
Other-than-serious | $0 | $0 | May 12, 2016 | Final |
| Citation 3, item 6 29 CFR 408.14923(1) |
Other-than-serious | $0 | $0 | May 12, 2016 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.1200(e)(1)
(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:
29 CFR 1910.134(k)(6)
(6) The basic advisory information on respirators, as presented in appendix D of this section, shall be provided by the employer in any written or oral format, to employees who wear respirators when such use is not required by this section or by the employer.
29 CFR 1910.147(c)(6)(i)
(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.
Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.