Inspection 346473762 OPENED FEB 1, 2023Closed
204 4th Avenue, Brooklyn, NY 11217 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Roma Electric Corp 4 times in New York since 2014.
The latest one began on Feb 1, 2023 as a planned inspection, in Brooklyn.
Those inspections ended with 3 citation items: 3 serious.
Penalties were first proposed at $6,400 and now stand at $3,500, 45% lower after settlements or reviews.
Ground-fault protection on job sites comes up most often in these citations: 2 items under 1926.404.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Roma Electric Corp averages $1,500 (1 cited inspection).
New York · latest 90 days of OSHA records
353employers cited
8 of them in the same industry
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Roma Electric Corp and get notified the morning OSHA posts a new citation for it.
Watch this company204 4th Avenue, Brooklyn, NY 11217 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
29-22 Northern Blvd, Long Island City, NY 11101 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
146 Waverly Place, New York, NY 10014 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites |
Serious | $2,800 | $1,500 | Jul 24, 2015 | Final |
89 Hicks St, Brooklyn, NY 11231 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites |
Serious | $2,000 | $1,200 | Oct 7, 2014 | Final |
| Citation 1, item 2 29 CFR 1926.404(f)(6) · Ground-fault protection on job sites |
Serious | $1,600 | $800 | Oct 7, 2014 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.403(i)(2)(i)
(2) Guarding of live parts. (i) Except as required or permitted elsewhere in this subpart, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by cabinets or other forms of enclosures, or by any of the following means:
29 CFR 1926.404(b)(1)(i)
(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.
29 CFR 1926.404(f)(6)
(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.