OSHA SearchOSHA records by employer

Roman Construction: OSHA inspections and violations

Andover, Massachusetts · Roofing Contractors · NAICS 238160

1inspections
2citation items
$2,800current penalties
May 13, 2016last inspection

OSHA inspectors have visited Roman Construction in Massachusetts one time.

It opened on May 13, 2016 on a referral, in Andover.

In all, OSHA issued 2 citation items: 2 serious.

The penalties, $2,800 in total, stand where OSHA first set them.

Among construction employers, the typical cited inspection since 2015 ends with a $3,079 penalty. Roman Construction averages $2,800 across 1 cited inspection.

Roman Construction: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Want to know if OSHA cites Roman Construction again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341476091 OPENED MAY 13, 2016Closed

Referral · Partial · Safety · 4 employees at the site · Closed Nov 28, 2017

44 Park Street, Andover, MA 01810 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$2,800$2,800Aug 1, 2016Final
Citation 1, item 1b
29 CFR 1926.1053(b)(12) · Ladders in construction
Serious$0$0Aug 1, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(12)

(12) Ladders shall have nonconductive siderails if they are used where the employee or the ladder could contact exposed energized electrical equipment, except as provided in § 1926.955(b) and (c) of this part.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(a)(1)

(a) Protection of employees. (1) No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.

Other roofing contractors employers in Massachusetts

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.