OSHA SearchOSHA records by employer

Romero Construction: OSHA inspections and violations

New Caney, Texas · Masonry Contractors · NAICS 238140

9inspections
22citation items
$20,631current penalties
Jan 30, 2023last inspection

OSHA has inspected Romero Construction 9 times in Texas since 1998.

The latest one began on Jan 30, 2023 to follow up on an earlier case, in New Caney.

Those inspections ended with 22 citation items: 19 serious and 3 other-than-serious.

Penalties were first proposed at $26,720 and now stand at $20,631, 23% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 11 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Romero Construction averages $11,810 (1 cited inspection).

Romero Construction: OSHA citation items per year, 1998 to 2023
Citation items per year, by inspection date.

Want to know if OSHA cites Romero Construction again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346468929 OPENED JAN 30, 2023Closed

Follow-up · Partial · Safety · 5 employees at the site · Closed Mar 9, 2023

21383 Valley Ranch Blvd., New Caney, TX 77357 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346139314 OPENED AUG 10, 2022Closed

Planned · Partial · Safety · 5 employees at the site · Closed Jan 12, 2026

21383 Valley Ranch Blvd., New Caney, TX 77357 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.28(a) · Personal protective equipment
Serious$2,486$2,486Sep 14, 2022Final
Citation 1, item 2a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$3,108$3,108Sep 14, 2022Final
Citation 1, item 2b
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Sep 14, 2022Final
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,108$3,108Sep 14, 2022Final
Citation 1, item 4
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$3,108$3,108Sep 14, 2022Final

Inspection 312155245 OPENED MAY 28, 2008Closed

Planned · Complete · Safety · 2 employees at the site · Closed Oct 1, 2009

1313 Fry Rd, Cypress, TX 77433 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,000$2,000Jun 27, 2008Closed

Inspection 310903257 OPENED APR 3, 2007Closed

Planned · Complete · Safety · 15 employees at the site · Closed Jul 5, 2007

4800 Liberty Blvd & Blue Jay Ave, La Joya, TX 78560 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$1,125$675Jun 6, 2007Closed
Citation 1, item 2
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$1,125$675Jun 6, 2007Closed
Citation 1, item 3
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$900$540Jun 6, 2007Closed
Citation 2, item 1
29 CFR 1926.25(a) · Housekeeping
Other-than-serious$0$0Jun 6, 2007Closed
Citation 2, item 2
29 CFR 1910.134(h)(3)(ia) · Respiratory protection
Other-than-serious$0$0Jun 6, 2007Closed

Inspection 310880638 OPENED MAR 6, 2007Closed

Planned · Partial · Safety · 22 employees at the site · Closed Jun 7, 2007

3101 San Mateo, Mission, TX 78572 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$510$306May 8, 2007Closed
Citation 2, item 1
29 CFR 1904.5(a) · Determination of work-relatedness
Other-than-serious$0$0May 8, 2007Closed

Inspection 309973857 OPENED MAY 24, 2006Closed

Planned · Complete · Safety · 7 employees at the site · Closed Jul 20, 2007

620 S Mccoll St & Paseo Del Bosque, Hidalgo, TX 78557 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,250$625Sep 28, 2006Closed
Citation 1, item 2
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$1,250$625Sep 28, 2006Closed
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,250$625Sep 28, 2006Closed
Citation 1, item 4
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$1,250$625Sep 28, 2006Closed
Citation 1, item 5
29 CFR 1926.451(g)(2) · Scaffolds, general requirements
Serious$1,250$625Sep 28, 2006Closed
Citation 1, item 6
29 CFR 1926.451(h)(2) · Scaffolds, general requirements
Serious$1,000$500Sep 28, 2006Closed
Citation 1, item 7
29 CFR 1926.602(c)(1)(vi) · Earthmovers and forklifts in construction
Serious$1,000$500Sep 28, 2006Closed
Citation 1, item 8a
29 CFR 1926.602(c)(1)(viiia) · Earthmovers and forklifts in construction
Serious$1,000$500Sep 28, 2006Closed
Citation 1, item 8b
29 CFR 1926.602(c)(1)(viiib) · Earthmovers and forklifts in construction
Serious$0$0Sep 28, 2006Closed

Inspection 309263713 OPENED SEP 14, 2005Closed

Unprogrammed other · Complete · Safety · 15 employees at the site · Closed Sep 16, 2005

2113 Us Hwy. 83, Roma, TX 78584 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 301576831 OPENED JAN 20, 2004Closed

Planned · Partial · Safety · 3 employees at the site · Closed Feb 24, 2004

3200 Block/joe Battle Blvd., El Paso, TX 79936 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

1 older inspection

Inspection 122186422 OPENED JUN 18, 1998Closed

Programmed related · Partial · Safety · 8 employees at the site · Closed Dec 17, 1998

11700 Lebanon Rd., Frisco, TX 75035 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.5 · Determination of work-relatedness

29 CFR 1904.5(a)

(a) Basic requirement. You must consider an injury or illness to be work-related if an event or exposure in the work environment either caused or contributed to the resulting condition or significantly aggravated a pre-existing injury or illness. Work-relatedness is presumed for injuries and illnesses resulting from events or exposures occurring in the work environment, unless an exception in § 1904.5(b)(2) specifically applies.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(h)(3)(ia)

(h) Maintenance and care of respirators. This paragraph requires the employer to provide for the cleaning and disinfecting, storage, inspection, and repair of respirators used by employees.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.25(a)

(a) During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, shall be kept cleared from work areas, passageways, and stairs, in and around buildings or other structures.

29 CFR 1926.28 · Personal protective equipment

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.602 · Earthmovers and forklifts in construction

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements