OSHA SearchOSHA records by employer

Romtec Inc: OSHA inspections and violations

Roseburg, Oregon · Prefabricated Metal Building and Component Manufacturing · NAICS 332311

6inspections
16citation items
$1,395current penalties
May 31, 2017last inspection

Since 2001, OSHA inspectors have visited Romtec Inc in Oregon 6 times.

The most recent inspection opened on May 31, 2017 to follow up on an earlier case, in Roseburg.

In all, OSHA issued 16 citation items: 5 serious and 11 other-than-serious.

The penalties, $1,395 in total, stand where OSHA first set them.

The rule cited most here is 1910.134 (respiratory protection), 3 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Romtec Inc averages $0 across 1 cited inspection.

Romtec Inc also files yearly injury logs with OSHA, summarized below.

Romtec Inc: OSHA citation items per year, 2001 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites Romtec Inc again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342366879 OPENED MAY 31, 2017Closed

Follow-up · Partial · Safety · 15 employees at the site · Closed May 31, 2017

18240 N Bank Rd, Roseburg, OR 97470 · Prefabricated Metal Building and Component Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342230679 OPENED APR 6, 2017Closed

Planned · Complete · Safety · 35 employees at the site · Closed Sep 1, 2017

18240 N Bank Rd, Roseburg, OR 97470 · Prefabricated Metal Building and Component Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(b)(1) · Walking-working surfaces
Other-than-serious$0$0May 2, 2017Final

Inspection 315932541 OPENED NOV 2, 2011Closed

Planned · Complete · Safety · 18 employees at the site · Closed Feb 23, 2012

18240 N Bank Rd, Roseburg, OR 97470 · Prefabricated Metal Building and Component Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(d)(2) · Electrical wiring methods
Serious$100$100Nov 18, 2011Closed
Citation 2, item 2 Other-than-serious$0$0Nov 18, 2011Closed

Inspection 310872742 OPENED NOV 15, 2007Closed

Planned · Complete · Safety · 25 employees at the site · Closed Mar 26, 2008

18240 N Bank Rd, Roseburg, OR 97470 · Prefabricated Metal Building and Component Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$165$165Dec 13, 2007Closed
Citation 1, item 1b
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$0$0Dec 13, 2007Closed
Citation 1, item 2 Serious$165$165Dec 13, 2007Closed
Citation 2, item 3
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Other-than-serious$0$0Dec 13, 2007Closed
Citation 2, item 4 Other-than-serious$0$0Dec 13, 2007Closed
Citation 2, item 5 Other-than-serious$200$200Dec 13, 2007Closed

Inspection 305733784 OPENED MAY 31, 2002Closed

Referral · Partial · Health · 25 employees at the site · Closed May 27, 2003

18240 N Bank Rd, Roseburg, OR 97470 · Plastics Plumbing Fixture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Nov 18, 2002Closed

Inspection 304658479 OPENED DEC 18, 2001Closed

Planned · Complete · Safety · 25 employees at the site · Closed Oct 30, 2002

18240 N Bank Rd, Roseburg, OR 97470 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$100$100Jan 17, 2002Closed
Citation 2, item 2
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0Jan 17, 2002Closed
Citation 2, item 3 Other-than-serious$500$500Jan 17, 2002Closed
Citation 2, item 4a
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$165$165Jan 17, 2002Closed
Citation 2, item 4b
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$0$0Jan 17, 2002Closed
Citation 2, item 4c
29 CFR 1910.134(f)(2) · Respiratory protection
Other-than-serious$0$0Jan 17, 2002Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Roseburg site logged 0 recordable injuries or illnesses among about 55 workers: 0.0 per 100 full-time workers, against a median of 0.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Romtec Inc
Roseburg · 2025
55 000.00.6

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1910.134(f)(2)

(2) Deep breathing. In a normal standing position, the subject shall breathe slowly and deeply, taking caution so as not to hyperventilate.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.22 · Walking-working surfaces

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.305 · Electrical wiring methods

29 CFR 7010.7001

29 CFR 7010.7650

29 CFR 7020.2270

29 CFR 7020.260

29 CFR 7020.410

Other prefabricated metal building and component manufacturing employers in Oregon