Rosecastle Management, LLC: OSHA inspections and violations
Zephyrhills, Florida · Assisted Living Facilities for the Elderly · NAICS 623312
1inspections
5citation items
$8,096current penalties
Oct 15, 2020last inspection
OSHA has inspected Rosecastle Management, LLC once in Florida.
The inspection began on Oct 15, 2020 after a complaint, in Zephyrhills.
That inspection ended with 5 citation items: 5 serious.
Penalties were first proposed at $13,494 and now stand at $8,096, 40% lower after settlements or reviews.
Electrical equipment, general requirements comes up most often in these citations: 3 items under 1910.303.
How that compares: the median penalty per cited inspection for health care employers since 2015 is $1,050, and Rosecastle Management, LLC averages $8,096 (1 cited inspection).
Rosecastle Management, LLC also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Florida · latest 90 days of OSHA records
326employers cited
Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch Rosecastle Management, LLC and get notified the morning OSHA posts a new citation for it.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2021, the Zephyrhills site logged 8 recordable injuries or illnesses among about 44 workers: 19.3 per 100 full-time workers, against a median of 5.5 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Rosecastle of Zephyrhills
Zephyrhills · 2021
44
8
0
19.3
5.5
Included with any plan: 3 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(ii) The floor of every workroom shall be maintained, so far as practicable, in a dry condition. Where wet processes are used, drainage shall be maintained and false floors, platforms, mats, or other dry standing places shall be provided, where practicable, or appropriate waterproof footgear shall be provided.
29 CFR 1910.303 · Electrical equipment, general requirements
29 CFR 1910.303(b)(6)
(6) Deteriorating agents. Unless identified for use in the operating environment, no conductors or equipment shall be located in damp or wet locations; where exposed to gases, fumes, vapors, liquids, or other agents that have a deteriorating effect on the conductors or equipment; or where exposed to excessive temperatures.
29 CFR 1910.303(b)(7)(iv)
(iv) There shall be no damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating.
Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.