OSHA SearchOSHA records by employer

Rossy Construction Corp.: OSHA inspections and violations

North Smithfield, Rhode Island · Roofing Contractors · NAICS 238160

3inspections
40citation items
$134,012current penalties
May 11, 2023last inspection

OSHA has inspected Rossy Construction Corp. 3 times in Rhode Island since 2021.

The latest one began on May 11, 2023 as a planned inspection, in Providence; the case is still open.

Those inspections ended with 40 citation items: 25 serious, 6 repeat and 9 other-than-serious.

Penalties were first proposed at $160,914 and now stand at $134,012, 17% lower after settlements or reviews.

Asbestos in construction comes up most often in these citations: 9 items under 1926.1101.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Rossy Construction Corp. averages $44,671 (3 cited inspections).

Rossy Construction Corp.: OSHA citation items per year, 2021 to 2023
Citation items per year, by inspection date.

Rhode Island · latest 90 days of OSHA records

84employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Rhode Island: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Rhode Island

Checking a subcontractor, a client or your own company? Watch Rossy Construction Corp. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346694730 OPENED MAY 11, 2023Open

Planned · Partial · Safety · 10 employees at the site · Open

180 Highland Avenue, Providence, RI 02906 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.502(d)(15) · Fall protection systems
Serious$5,156$5,156Sep 6, 2023Final
Citation 1, item 1b
29 CFR 1926.502(d)(17) · Fall protection systems
Serious$0$0Sep 6, 2023Final
Citation 1, item 2a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$5,156$5,156Sep 6, 2023Final
Citation 1, item 2b
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$0$0Sep 6, 2023Final
Citation 1, item 2c
29 CFR 1926.1053(b)(8) · Ladders in construction
Serious$0$0Sep 6, 2023Final
Citation 1, item 2d
29 CFR 1926.1053(b)(9) · Ladders in construction
Serious$0$0Sep 6, 2023Final
Citation 1, item 2e
29 CFR 1926.1053(b)(10) · Ladders in construction
Serious$0$0Sep 6, 2023Final
Citation 1, item 2f
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$0$0Sep 6, 2023Final
Citation 1, item 2g
29 CFR 1926.1053(b)(21) · Ladders in construction
Serious$0$0Sep 6, 2023Final
Citation 1, item 2h
29 CFR 1926.1053(b)(22) · Ladders in construction
Serious$0$0Sep 6, 2023Final
Citation 2, item 1
29 CFR 1926.100(a) · Hard hats in construction
Repeat$25,781$25,781Sep 6, 2023Final
Citation 2, item 2
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Repeat$25,781$25,781Sep 6, 2023Final
Citation 2, item 3
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$25,781$25,781Sep 6, 2023Final
Citation 3, item 1
29 CFR 1926.25(a) · Housekeeping
Other-than-serious$413$413Sep 6, 2023Final
Citation 3, item 2
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$413$413Sep 6, 2023Final
Citation 3, item 3
29 CFR 1926.1053(b)(15) · Ladders in construction
Other-than-serious$413$413Sep 6, 2023Final
Citation 4, item 1a
29 CFR 1903.19(c)(1) · Proving cited hazards were fixed
Other-than-serious$413$413Dec 4, 2023Final
Citation 4, item 1b
29 CFR 1903.19(d)(1) · Proving cited hazards were fixed
Other-than-serious$0$0Dec 4, 2023Final

Inspection 346608862 OPENED APR 3, 2023Closed

Referral · Partial · Safety · 15 employees at the site · Closed Jul 6, 2026

83 Prospect St., Pawtucket, RI 02860 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$6,250$3,125Jul 17, 2023Final
Citation 1, item 2
29 CFR 1926.451(c)(3) · Scaffolds, general requirements
Serious$6,250$3,125Jul 17, 2023Final
Citation 1, item 3a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$6,250$3,125Jul 17, 2023Final
Citation 1, item 3b
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Jul 17, 2023Final
Citation 1, item 4
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$6,250$3,125Jul 17, 2023Final
Citation 1, item 5
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$3,572$1,786Jul 17, 2023Final
Citation 2, item 1a
29 CFR 1903.19(c)(1) · Proving cited hazards were fixed
Other-than-serious$501$501Dec 4, 2023Final
Citation 2, item 1b
29 CFR 1903.19(d)(1) · Proving cited hazards were fixed
Other-than-serious$0$0Dec 4, 2023Final

Inspection 345212518 OPENED MAR 17, 2021Closed

Complaint · Partial · Health · 14 employees at the site · Closed Aug 25, 2023

254 Great Road, North Smithfield, RI 02896 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.1101(f)(1)(i) · Asbestos in construction
Serious$6,007$4,205Aug 2, 2021Final
Citation 1, item 1b
29 CFR 1926.1101(g)(3)(iii) · Asbestos in construction
Serious$0$0Aug 2, 2021Final
Citation 1, item 1c
29 CFR 1926.1101(g)(7)(i) · Asbestos in construction
Serious$0$0Aug 2, 2021Final
Citation 1, item 1d
29 CFR 1926.1101(g)(8)(iii)(b) · Asbestos in construction
Serious$0$0Aug 2, 2021Final
Citation 1, item 1e
29 CFR 1926.1101(g)(8)(iii)(c) · Asbestos in construction
Serious$0$0Aug 2, 2021Final
Citation 1, item 1f
29 CFR 1926.1101(h)(1)(iv) · Asbestos in construction
Serious$0$0Aug 2, 2021Final
Citation 1, item 1g
29 CFR 1926.1101(i)(1) · Asbestos in construction
Serious$0$0Aug 2, 2021Final
Citation 1, item 1h
29 CFR 1926.1101(k)(3)(i) · Asbestos in construction
Serious$0$0Aug 2, 2021Final
Citation 1, item 1i
29 CFR 1926.1101(k)(9)(i) · Asbestos in construction
Serious$0$0Aug 2, 2021Final
Citation 2, item 1
29 CFR 1926.100(a) · Hard hats in construction
Repeat$12,015$8,410Aug 2, 2021Final
Citation 2, item 2
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Repeat$12,015$8,410Aug 2, 2021Final
Citation 2, item 3
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$12,015$8,410Aug 2, 2021Final
Citation 3, item 1a
29 CFR 1903.19(c)(1) · Proving cited hazards were fixed
Other-than-serious$482$482Oct 12, 2021Final
Citation 3, item 1b
29 CFR 1903.19(d)(1) · Proving cited hazards were fixed
Other-than-serious$0$0Oct 12, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.19 · Proving cited hazards were fixed

29 CFR 1903.19(c)(1)

(c) Abatement certification. (1) Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section.

29 CFR 1903.19(d)(1)

(d) Abatement documentation. (1) The employer must submit to the Agency, along with the information on abatement certification required by paragraph (c)(3) of this section, documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1101 · Asbestos in construction

29 CFR 1926.25 · Housekeeping

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Rhode Island

Alert subscribers get notified of each newly cited employer in Rhode Island the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.