OSHA SearchOSHA records by employer

Route 21 Homes LLC: OSHA inspections and violations

Greensburg, Pennsylvania · All Other Specialty Trade Contractors · NAICS 238990

1inspections
10citation items
$6,677current penalties
Jun 16, 2016last inspection

OSHA has inspected Route 21 Homes LLC once in Pennsylvania.

The inspection began on Jun 16, 2016 on a referral, in Greensburg.

That inspection ended with 10 citation items: 10 serious.

Penalties were first proposed at $13,362 and now stand at $6,677, 50% lower after settlements or reviews.

Exit routes comes up most often in these citations: 2 items under 1910.37.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Route 21 Homes LLC averages $6,677 (1 cited inspection).

It reported 1 severe injury to OSHA since 2015.

Route 21 Homes LLC: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

277employers cited

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Route 21 Homes LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341564003 OPENED JUN 16, 2016Closed

Referral · Partial · Safety · 3 employees at the site · Closed Feb 17, 2017

334 Monkey Wrench Road, Greensburg, PA 15601 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.37(b)(2) · Exit routes
Serious$2,138$1,069Sep 6, 2016Final
Citation 1, item 1b
29 CFR 1910.37(b)(5) · Exit routes
Serious$0$0Sep 6, 2016Final
Citation 1, item 2a
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$2,138$1,069Sep 6, 2016Final
Citation 1, item 2b
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Serious$0$0Sep 6, 2016Final
Citation 1, item 2c
29 CFR 1910.303(e)(1)(ii) · Electrical equipment, general requirements
Serious$0$0Sep 6, 2016Final
Citation 1, item 3
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$2,138$1,069Sep 6, 2016Final
Citation 1, item 4
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$3,741$1,870Sep 6, 2016Final
Citation 1, item 5a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,207$1,600Sep 6, 2016Final
Citation 1, item 5b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Sep 6, 2016Final
Citation 1, item 5c
29 CFR 1926.21(b)(2) · Construction safety training
Serious$0$0Sep 6, 2016Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jun 8, 2016, Greensburg: Hospitalization · fractures · finger(s), fingernail(s), n.e.c.

An employee was installing concrete blocks onto a modular home's concrete piers to level a double-wide trailer. A block fell onto his left middle finger and fractured it.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(e)(1)(ii)

(ii) Other markings giving voltage, current, wattage, or other ratings as necessary.

29 CFR 1910.303(g)(1)

(1) Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

29 CFR 1926.21 · Construction safety training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.95 · Criteria for personal protective equipment

Other all other specialty trade contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.