Inspection 348454091 OPENED AUG 15, 2025Closed
Walmsley Gardens 4850 Walmsley Boulevard, Richmond, VA 23224 · Siding Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Royal Homes Inc 15 times in Virginia since 1999.
The latest one began on Aug 15, 2025, in Richmond.
Those inspections ended with 28 citation items: 22 serious, 2 repeat and 4 other-than-serious.
Penalties were first proposed at $18,290 and now stand at $11,685, 36% lower after settlements or reviews.
Scaffolds, general requirements comes up most often in these citations: 7 items under 1926.451.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Royal Homes Inc averages $1,390 (4 cited inspections).
Virginia · latest 90 days of OSHA records
249employers cited
3 of them in the same industry
Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Virginia
Checking a subcontractor, a client or your own company? Watch Royal Homes Inc and get notified the morning OSHA posts a new citation for it.
Watch this companyWalmsley Gardens 4850 Walmsley Boulevard, Richmond, VA 23224 · Siding Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
12310 Moores Lake Rd., Chester, VA 23831 · Siding Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
12770 Nettles Drive, Newport News, VA 23606 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2130 Marina Shores Drive, Virginia Beach, VA 23463 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.502(d)(16)(iii) · Fall protection systems |
Serious | $3,780 | $2,646 | Feb 5, 2020 | Final |
2309 Point Chesapeake Quay, Virginia Beach, VA 23451 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1808 Mediterranean Ave., Virginia Beach, VA 23451 · Siding Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
3955 Fair Ridge Drive, Fairfax, VA 22033 · Siding Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.502(d)(16)(iii) · Fall protection systems |
Serious | $1,425 | $855 | Apr 27, 2017 | Final |
4601 Spotsylvania Parkway, Fredericksburg, VA 22401 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.100(a) · Hard hats in construction |
Serious | $495 | $396 | Jun 17, 2016 | Final |
| Citation 1, item 2 29 CFR 1926.501(b)(13) · Fall protection in construction |
Serious | $2,280 | $684 | Jun 17, 2016 | Final |
728 Cameron Street, Franklin, VA 23851 · Residential Remodelers · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.503(a)(2)(iii) · Fall protection training in construction |
Serious | $1,400 | $980 | Apr 9, 2015 | Final |
6490 Park Crescent Way, Norfolk, VA 23513 · Siding Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.452(j)(2) · Rules for each type of scaffold |
Serious | $735 | $514 | Jul 26, 2012 | Closed |
| Citation 2, item 1 29 CFR 1926.451(c)(2) · Scaffolds, general requirements |
Other-than-serious | $0 | $0 | Jul 26, 2012 | Closed |
100 E. 15th Street, Norfolk, VA 23501 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.100(a) · Hard hats in construction |
Serious | $500 | $300 | Dec 6, 2005 | Closed |
| Citation 1, item 2 29 CFR 1926.501(b)(11) · Fall protection in construction |
Serious | $625 | $375 | Dec 6, 2005 | Closed |
| Citation 2, item 1 29 CFR 1926.50(c) · Medical services and first aid |
Other-than-serious | $0 | $0 | Dec 6, 2005 | Closed |
| Citation 2, item 2 29 CFR 1926.51(c)(1) · Sanitation |
Other-than-serious | $0 | $0 | Dec 6, 2005 | Closed |
1601 Granby Street, Norfolk, VA 23510 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
The Park At Salisbury, 301 N. Otterdale Road, Midlothian, VA 23113 · Siding Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements |
Serious | $625 | $375 | May 4, 2004 | Closed |
New Home Construction, 1019 Mitford Place, Midlothian, VA 23113 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.100(a) · Hard hats in construction |
Repeat | $1,200 | $900 | Aug 20, 2001 | Closed |
| Citation 1, item 2 29 CFR 1926.501(b)(11) · Fall protection in construction |
Repeat | $2,000 | $1,500 | Aug 20, 2001 | Closed |
| Citation 2, item 1 29 CFR 1926.1053(b)(1) · Ladders in construction |
Other-than-serious | $600 | $360 | Aug 20, 2001 | Closed |
The Glens At Millers Lane Apts., 4700 Millers Lane, Sandston, VA 23229 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.100(a) · Hard hats in construction |
Serious | $375 | $200 | Nov 22, 1999 | Final |
| Citation 1, item 2a 29 CFR 1926.150(a)(1) · Fire protection |
Serious | $225 | $100 | Nov 22, 1999 | Final |
| Citation 1, item 2b 29 CFR 1926.150(c)(1)(i) · Fire protection |
Serious | $0 | $0 | Nov 22, 1999 | Final |
| Citation 1, item 2c 29 CFR 1926.150(c)(1)(iv) · Fire protection |
Serious | $0 | $0 | Nov 22, 1999 | Final |
| Citation 1, item 3a 29 CFR 1926.451(b)(2)(i) · Scaffolds, general requirements |
Serious | $1,500 | $1,200 | Nov 22, 1999 | Final |
| Citation 1, item 3b 29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements |
Serious | $0 | $0 | Nov 22, 1999 | Final |
| Citation 1, item 3c 29 CFR 1926.451(c)(2) · Scaffolds, general requirements |
Serious | $0 | $0 | Nov 22, 1999 | Final |
| Citation 1, item 3d 29 CFR 1926.451(f)(7) · Scaffolds, general requirements |
Serious | $0 | $0 | Nov 22, 1999 | Final |
| Citation 1, item 3e 29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements |
Serious | $0 | $0 | Nov 22, 1999 | Final |
| Citation 1, item 3f 29 CFR 1926.452(j)(2) · Rules for each type of scaffold |
Serious | $0 | $0 | Nov 22, 1999 | Final |
| Citation 1, item 4 29 CFR 1926.501(b)(1) · Fall protection in construction |
Serious | $300 | $200 | Nov 22, 1999 | Final |
| Citation 1, item 5a 29 CFR 1926.1053(a)(2) · Ladders in construction |
Serious | $225 | $100 | Nov 22, 1999 | Final |
| Citation 1, item 5b 29 CFR 1926.1053(b)(1) · Ladders in construction |
Serious | $0 | $0 | Nov 22, 1999 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.100(a)
(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.
29 CFR 1926.1053(a)(2)
(2) Ladder rungs, cleats, and steps shall be parallel, level, and uniformly spaced when the ladder is in position for use.
29 CFR 1926.1053(b)(1)
(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.
Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.