OSHA SearchOSHA records by employer

RP Remodeling, LLC: OSHA inspections and violations

Brookfield, Connecticut · Roofing Contractors · NAICS 238160

5inspections
26citation items
$56,590current penalties
Jul 26, 2019last inspection

Since 2015, OSHA inspectors have visited RP Remodeling, LLC in Connecticut 5 times.

The most recent inspection opened on Jul 26, 2019 to follow up on an earlier case, in Brookfield.

In all, OSHA issued 26 citation items: 22 serious and 4 repeat.

The proposed penalties came to $79,176; today they stand at $56,590, 29% less.

The rule cited most here is 1926.1053 (ladders in construction), 10 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. RP Remodeling, LLC averages $14,148 across 4 cited inspections.

1 inspection on this page followed a fatal incident.

RP Remodeling, LLC: OSHA citation items per year, 2015 to 2019
Citation items per year, by inspection date.

Connecticut · latest 90 days of OSHA records

86employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Connecticut: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Connecticut

Checking a subcontractor, a client or your own company? Watch RP Remodeling, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344185731 OPENED JUL 26, 2019Closed

Follow-up · Records only · Safety · 5 employees at the site · Closed Jul 26, 2019

21 Oak Meadows Drive, Brookfield, CT 06804 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342874062 OPENED JAN 11, 2018Closed

Planned · Partial · Safety · 5 employees at the site · Closed Jun 29, 2023

21 Oak Meadows Dr., Brookfield, CT 06804 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$3,049$2,130Feb 14, 2018Final
Citation 2, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$21,341$16,000Feb 14, 2018Final
Citation 2, item 2
29 CFR 1926.503(a)(1) · Fall protection training in construction
Repeat$15,244$11,000Feb 14, 2018Final

Inspection 342302965 OPENED MAY 4, 2017Closed

Planned · Partial · Safety · 2 employees at the site · Closed Sep 23, 2022

White Tail Lane, Shelton, CT 06484 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(11) · Fall protection in construction
Repeat$8,366$6,400Jun 13, 2017Final
Citation 1, item 2
29 CFR 1926.503(a)(1) · Fall protection training in construction
Repeat$5,976$4,600Jun 13, 2017Final

Inspection 340615640 OPENED APR 30, 2015Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Mar 9, 2018

575 Carroll Avenue, Bridgeport, CT 06608 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$2,000$1,300Sep 16, 2015Final
Citation 1, item 2a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,800$1,840Sep 16, 2015Final
Citation 1, item 2b
29 CFR 1926.451(e)(8) · Scaffolds, general requirements
Serious$0$0Sep 16, 2015Final
Citation 1, item 3a
29 CFR 1926.451(g)(1)(i) · Scaffolds, general requirements
Serious$2,800$1,840Sep 16, 2015Final
Citation 1, item 3b
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Sep 16, 2015Final
Citation 1, item 3c
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$0$0Sep 16, 2015Final
Citation 1, item 4a
29 CFR 1926.454(a) · Scaffold training
Serious$2,000$1,300Sep 16, 2015Final
Citation 1, item 4b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Sep 16, 2015Final
Citation 1, item 4c
29 CFR 1926.1060(a) · Ladder and stairway training
Serious$0$0Sep 16, 2015Final
Citation 1, item 5a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,800$1,840Sep 16, 2015Final
Citation 1, item 5b
29 CFR 1926.1053(b)(5)(i) · Ladders in construction
Serious$0$0Sep 16, 2015Final
Citation 1, item 5c
29 CFR 1926.1053(b)(10) · Ladders in construction
Serious$0$0Sep 16, 2015Final
Citation 1, item 6a
29 CFR 1926.1053(b)(15) · Ladders in construction
Serious$1,600$1,040Sep 16, 2015Final
Citation 1, item 6b
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$0$0Sep 16, 2015Final
Citation 1, item 7a
29 CFR 1926.1053(b)(21) · Ladders in construction
Serious$2,800$1,840Sep 16, 2015Final
Citation 1, item 7b
29 CFR 1926.1053(b)(22) · Ladders in construction
Serious$0$0Sep 16, 2015Final

Inspection 340185875 OPENED JAN 16, 2015Closed

Fatality or catastrophe · Partial · Safety · 7 employees at the site · Closed Jan 9, 2017

466 Willard Avenue, Newington, CT 06111 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jan 21, 2015 (fatal): An employee receives electric shock and falls from ladder wh

At 10:15 p.m. on January 21, 2105, an employee was carrying a piece of aluminum flashing up a ladder. The victim lost control of the flashing in the windy conditions. The flashing contacted the adjacent energized power line. The victim was electrically shocked which caused him to fall approximately 18 feet from the ladder. Employee succumbed to injuries and died.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$2,800$1,820Feb 5, 2015Final
Citation 1, item 2
29 CFR 1926.1053(b)(12) · Ladders in construction
Serious$2,800$1,820Feb 5, 2015Final
Citation 1, item 3a
29 CFR 1926.1060(a) · Ladder and stairway training
Serious$2,800$1,820Feb 5, 2015Final
Citation 1, item 3b
29 CFR 1926.1053(b)(21) · Ladders in construction
Serious$0$0Feb 5, 2015Final
Citation 1, item 3c
29 CFR 1926.1053(b)(22) · Ladders in construction
Serious$0$0Feb 5, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(10)

(10) The top of a non-self-supporting ladder shall be placed with the two rails supported equally unless it is equipped with a single support attachment.

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Connecticut

Alert subscribers get notified of each newly cited employer in Connecticut the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.