OSHA SearchOSHA records by employer

Rubicon Builders, LLC: OSHA inspections and violations

Revere, Massachusetts · Industrial Building Construction · NAICS 236210

5inspections
2citation items
$5,082current penalties
Mar 20, 2025last inspection

OSHA has inspected Rubicon Builders, LLC 5 times in Massachusetts since 2016.

The latest one began on Mar 20, 2025 after a complaint, in Revere.

Those inspections ended with 2 citation items: 2 other-than-serious.

Penalties were first proposed at $13,904 and now stand at $5,082, 63% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Rubicon Builders, LLC averages $2,541 (2 cited inspections).

Rubicon Builders, LLC: OSHA citation items per year, 2016 to 2025
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

242employers cited

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch Rubicon Builders, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348125956 OPENED MAR 20, 2025Closed

Complaint · Partial · Safety · 3 employees at the site · Closed Nov 17, 2025

93 Bennington St., Revere, MA 02151 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347518441 OPENED MAY 31, 2024Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Apr 24, 2025

93 Bennington Street, Revere, MA 02151 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(f)(6) · Scaffolds, general requirements
Other-than-serious$10,163$5,082Oct 22, 2024Final

Inspection 346601396 OPENED MAR 27, 2023Closed

Planned · Complete · Safety · 30 employees at the site · Closed Apr 26, 2023

416 Cambridge Street, Winchester, MA 01890 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345390637 OPENED JUN 30, 2021Closed

Complaint · Partial · Safety · 25 employees at the site · Closed Jul 6, 2021

105 Washington Street, Brighton, MA 02135 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341816361 OPENED OCT 5, 2016Closed

Referral · Partial · Safety · 2 employees at the site · Closed May 5, 2017

2-4 North Main Street, Sherborn, MA 01770 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.150(a)(4) · Fire protection
Other-than-serious$3,741$0Dec 12, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(a)(4)

(4) All firefighting equipment shall be periodically inspected and maintained in operating condition. Defective equipment shall be immediately replaced.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(6)

(6) The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows:

Other industrial building construction employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.