OSHA SearchOSHA records by employer

Rudder Electric, Inc.: OSHA inspections and violations

Jeffersonville, Indiana · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

5inspections
17citation items
$2,275current penalties
Mar 3, 2026last inspection

Rudder Electric, Inc. has 5 OSHA inspections on record in Indiana, the first in 2001.

OSHA's last visit started on Mar 3, 2026 as a planned inspection, in Jeffersonville.

Across those inspections OSHA issued 17 citation items: 5 serious, 2 repeat and 10 other-than-serious.

OSHA proposed $2,275 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.405, job-site wiring (6 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Rudder Electric, Inc. averages $1,400 over 1 cited inspection in that time.

Rudder Electric, Inc.: OSHA citation items per year, 2001 to 2026
Citation items per year, by inspection date.

Indiana · latest 90 days of OSHA records

81employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Indiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Indiana

Checking a subcontractor, a client or your own company? Watch Rudder Electric, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348781857 OPENED MAR 3, 2026Closed

Planned · Complete · Safety · 4 employees at the site · Closed Jun 8, 2026

826 E Lewis & Clark Pkwy., Jeffersonville, IN 47130 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(13) · Ladders in construction
Serious$1,400$1,400Apr 1, 2026Final

Inspection 316545847 OPENED NOV 28, 2012Closed

Unprogrammed other · Complete · Safety · 2 employees at the site · Closed Nov 30, 2012

107 Craig Park, Scottsburg, IN 47170 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 307419762 OPENED APR 26, 2004Closed

Planned · Complete · Safety · 5 employees at the site · Closed Feb 15, 2005

2008 Spring St., Jeffersonville, IN 47130 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(d)(1) · Electrical equipment on job sites
Repeat$100$100Aug 24, 2004Closed
Citation 1, item 2
29 CFR 1926.405(a)(2)(iie) · Job-site wiring
Repeat$100$100Aug 24, 2004Closed
Citation 2, item 1
29 CFR 1926.150(c)(1)(i) · Fire protection
Other-than-serious$0$0Aug 24, 2004Closed
Citation 2, item 2
29 CFR 1926.405(a)(2)(iif) · Job-site wiring
Other-than-serious$0$0Aug 24, 2004Closed

Inspection 305640088 OPENED SEP 26, 2002Closed

Planned · Complete · Safety · 1 employee at the site · Closed Jan 17, 2003

Austin Elementary School Renovation, Austin, IN 47102 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 302009915 OPENED JUN 18, 2001Closed

Planned · Complete · Safety · 2 employees at the site · Closed Dec 3, 2001

Library Addition/ Renovation, Salem, IN 47167 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.21(b)(2) · Construction safety training
Serious$225$225Oct 30, 2001Closed
Citation 1, item 1b
29 CFR 1926.1060(b) · Ladder and stairway training
Serious$0$0Oct 30, 2001Closed
Citation 1, item 2
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$225$225Oct 30, 2001Closed
Citation 1, item 3
29 CFR 1926.502(b)(2) · Fall protection systems
Serious$225$225Oct 30, 2001Closed
Citation 2, item 1
29 CFR 1926.403(d)(1) · Electrical equipment on job sites
Other-than-serious$0$0Oct 30, 2001Closed
Citation 2, item 2
29 CFR 1926.403(h) · Electrical equipment on job sites
Other-than-serious$0$0Oct 30, 2001Closed
Citation 2, item 3
29 CFR 1926.405(a)(2)(iie) · Job-site wiring
Other-than-serious$0$0Oct 30, 2001Closed
Citation 2, item 4
29 CFR 1926.405(b)(1) · Job-site wiring
Other-than-serious$0$0Oct 30, 2001Closed
Citation 2, item 5
29 CFR 1926.405(b)(2) · Job-site wiring
Other-than-serious$0$0Oct 30, 2001Closed
Citation 2, item 6
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$0$0Oct 30, 2001Closed
Citation 2, item 7
29 CFR 1926.1052(b)(1) · Stairways in construction
Other-than-serious$0$0Oct 30, 2001Closed
Citation 2, item 8
29 CFR 1926.1052(c)(1)(ii) · Stairways in construction
Other-than-serious$0$0Oct 30, 2001Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(b)(1)

(1) Except during stairway construction, foot traffic is prohibited on stairways with pan stairs where the treads and/or landings are to be filled in with concrete or other material at a later date, unless the stairs are temporarily fitted with wood or other solid material at least to the top edge of each pan. Such temporary treads and landings shall be replaced when worn below the level of the top edge of the pan.

29 CFR 1926.1052(c)(1)(ii)

(ii) One stairrail system along each unprotected side or edge.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(13)

(13) The top or top step of a stepladder shall not be used as a step.

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.150 · Fire protection

29 CFR 1926.21 · Construction safety training

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.502 · Fall protection systems

Other electrical contractors and other wiring installation contractors employers in Indiana

Alert subscribers get notified of each newly cited employer in Indiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.